Commissioning; Functional Check - Leuze lumiflex Compact C14 Series Connecting And Operating Instructions

Safety light curtains and light grids
Table of Contents

Advertisement

6

Commissioning

6.1

Functional Check

The correctness of the connections and the supply voltage (+24 V DC ± 20 %) shall be checked
before switching the equipment on for the first time.
The LED's and the 7-segment displays indicate the system status of transmitter and receiver when
the supply voltage is turned on:
7-segment display
8.(only in the instant of
being turned on)
S (for approx. 1 s)
1 or 2
. (decimal point
turned on)
F
Receiver LED's
Green illuminated
Green + orange
illuminated
Red illuminated
Yellow illuminated
(This function is only
available together with
a future intelligent
interface.)
72
System status
transmitter
Hardware reset
Self-test running
Normal operation,
channel 1 or channel 2
set
Test input open,
testing activated
Discrepancy in unit or
circuitry
System status
OSSD's on,
adequate reception of light at all light planes
OSSD's on,
weak reception of light at one or more light planes
=> Perform fine adjustment of transmitter and
receiver
OSSD's off,
at least one plane of light interrupted or transmitter
tester input open (decimal point in transmitter dis-
play illuminated)
Safety sequencing circuit signals
„Operator invention required" =>
- Operate command unit Start/Restart, or
- Unit waiting for insertion or removal of workpiece
for activated clocked control.
COMPACT
System status
receiver
Hardware reset
Self-test running
Normal operation, chan-
nel 1 or channel 2 set
Multiple scanning
d-scan set
Discrepancy in unit or
circuitry
Leuze
lumiflex