Installation Specifications For Compact Light Grids For Danger Area Safeguard, Horizontal Arrangement (Series C50 And C90) - Leuze lumiflex Compact C14 Series Connecting And Operating Instructions

Safety light curtains and light grids
Table of Contents

Advertisement

4.4
Installation Specifications for COMPACT Light Grids for Danger Area Safe-
guard, Horizontal Arrangement (Series C50 and C90)
When light grids, horizontal arrangement are being mounted to safeguard danger areas, make sure
that the height of the sensing field does not exceed 1000 mm above the ground. If H exceeds 300
mm (200 mm if children are present), an undetected approach underneath the sensing field is pos-
sible. This must be taken into account when the risk is assessed. The lowest admissible height for
grid assembly depends on the AOPDs resolution, to ensure that the human leg or foot can be
recognized without failure. The minimum safety distance is calculated as follows:
S = (1.6 mm/ms x T) + C
C = 1200 mm - 0.4 x H
(with H = height of the sensing field above reference plane C
Assembly height:
H
= 1000 mm
max
H
= 15 (d - 50 mm) with d = resolution of the AOPD
min
The admissible height for grid assemblies of the COMPACT light grids by using this calculation is:
COMPACT Series
C50
C90
Fig. 15
Clearance and installation height for horizontal protection against dangerous areas
64
Height of the Sensing Field above
Reference Plane
from ... to
0 mm ... 1000 mm
600 mm ... 1000 mm
COMPACT
= 850 mm)
min
H
S
Leuze
lumiflex

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents