3.3

Cascading

COMPACT basic and follower equipment can be connected in succession in order to realise linked
protection zones. Units of different resolution can thereby be combined with up to 240 planes of
light (e.g. a basic unit 1650 mm with 14 mm resolution as finger protection and a follower unit with
450 mm and 50 mm resolution as step-over protection), see Table 2, Page 78. The follower units
are available starting at a protection height of 150 mm and in graduations of 150 mm.
1 channel 1
2 channel 2
.
d-scan
5 selftest
F failure
reset/action
receiver
a
Fig. 6
Cascading of basic and follower units over plug-in cable connection
3.4

Display Elements

COMPACT
Transmitter CT
Fig. 7
Display elements in transmitter and in receiver
54
a
=
master
b
=
slave with 250 mm cable and
M12 connector, 8pol + shield
b
*
COMPACT
COMPACT
Receiver CR
a
=
b
=
c
=
d
=
e
=
f
=
*
=
system status
test active
multiple analysis d-scan active
outputs OSSD off
outputs OSSD on
weak receiving signals
display reserved for future
expansion of functions
Leuze
lumiflex