Leuze lumiflex Compact C14 Series Connecting And Operating Instructions page 28

Safety light curtains and light grids
Table of Contents

Advertisement

a
=
connecting pins
b
=
switches for adjusting parameters
c
=
pin receptables
d
=
indicator screw plug PG 9
e
=
PG 13,5
Fig. 19
The terminal caps can be removed once the screws have been loosened.
One option which is available is to use terminal caps with connector inserts (DIN 43651, 6-pin + PE) and
matching cable sockets in straight or angled or with Brad-Harrison-Min connection and matching cable
versions.
PG 9
7 6 5 4 3 2 1
PG
13,5
S1 S2 S3
Fig. 20
Plugable connecting cap with screw terminals (included in the scope of supply)
*) Jumper only factory-set in connecting cap of transmitter with PG 13.5. In case of plugable devices the
jumper has to be set externally.
70
.
Terminal assignment
Clamp,
Transmitter
Connector
CT
1
+ 24 V
2
0 V
3
Test out
4
Test in
5
- RS-485
6
+ RS-485 (S1
7
PE, shield
COMPACT
Receiver
CR
+ 24 V
0 V
OSSD1
Jumper has been
OSSD2
factory-set already *)
- RS-485
)
select: + RS-485 (S1
pnp contamination and
disturbance output (S1
PE, shield
) or
)
Leuze