Operating Mode - Leuze lumiflex Compact C14 Series Connecting And Operating Instructions

Safety light curtains and light grids
Table of Contents

Advertisement

Fig. 5
COMPACT System design
3.2

Operating Mode

The COMPACT works in the operating mode „Protection operating mode without restart disable".
Reception of all light planes switches the output voltage at the OSSD's to +24 V. Interruption of one
or more light planes shuts off the output voltage at the OSSD's within the response time for the sys-
tem. The OSSD's automatically revert to +24 V as soon as the planes of light are free again.
Additional functions such as restart disable and protection control can be realised by the safety
relays MSI-SR2/F or MSI-SR2 or directly from a fail-safe PLC (refer to Chapter 5.2). For additional
intelligent functions like single break/double break or muting the modular safety interfaces of the MSI
series can be connected.
Leuze
lumiflex
a
=
connecting caps
b
=
control electronic
c
=
IR transmitter module
d
=
control and evaluation electronic
e
=
IR receiver module
f
=
cap
g
=
aluminium profile
COMPACT
53