4-4-1 Sync. signal timing
RDSYNC
(line trigger
RDSYNC
signal)
(Trigger)
More than 19.8us (*1)
More than TBD us
T.B.D
Valid pixels output
PIXEL DATA
1st_PIXEL
*1 22.2usec (for L4 only) 26.6usec (for L5/L6) is the min.
scan period at 600 dpi output. Each min. scan period in
different output modes is different.
TM-XJ101C
4-4 Sync signal timing (External sync mode)
End_PIXEL
【External sync. mode】
*The initial setting of this product is internal sync. mode.
1) To operate CIS at external sync. mode,
line trigger signal (RDSYNC at left diagram) has to be input
through the 1
block, Master port (D1).
st
2) For scan operation, the scan cycle is decided by RDSYNC
startup timing.
Secure "H" term (more than 3.8us) of RDSYNC.
3) If you input the sync. signal created by an encoder on the
object conveyer through the Grabber boards, the scan
timing of this product can be synchronized with the motion
of the object.
【Remarks】
1) Input/set the longer sync. signal cycle than the line cycle.
Improper image data is output if the sync signal cycle is
shorter than necessary line cycle.
2) Do not use TBD lines just after sync. signal input.
(Invalid data is output due to the internal line delay)