Extension Settings In Caracas Desk - Siemens Caracas Desk Rel. 2.0 Service Manual

Table of Contents

Advertisement

Nur für den internen Gebrauch
The extension 64 (with the default extension number 263) in Hicom is to be grant-
ed the level of access that a guest telephone with trunk access should receive
(e.g. all lines unrestricted trunk access).

4.6.3 Extension settings in Caracas Desk

Load the current extension numbers to Caracas Desk via the Settings/Basic set-
tings/Read customer data menu.
Once the numbers have been successfully loaded (indicated by a flashing Alarm
LED), select the menu item Settings/Basic settings/Extensions.
Set the extension types and, if necessary, the extension numbers. Extensions 1-
6 are preconfigured by default as administration. The preconfigured extensions
are to be modified in accordance with requirements. The following items of infor-
mation are necessary for each extension:
Enter the required room number.
The Hicom number represents the physical connection PEN in Hicom.
Example: the U
1, 2, 3, etc.
These numbers cannot be changed. However, they can be removed as re-
quired by deleting extensions and specified by adding extensions.
Enter the required extension number. The internal extension number and the
DDI number of the extension are simultaneously changed.
In the case of a 3-digit extension number and an S
DDI has been released by your local network provider.
Type:
Guest: Guest extensions
Booth1/booth2: telephone booths. As in the case of "guests", individual
calls are itemized. On check-out, the name is not deleted and the status is
immediately set to "free". If a name is not specified at check-in, the original
name is retained. An individual charge factor and minimum charge can be
set for the telephone booth.
Service: service extensions such as the reception, kitchen, etc. as for "tele-
phone booth". In the event of check-out or payment, however, trunk access
is not switched.
Services without charges: service extensions for which only the charge to-
tal is recorded: no details of the individual calls are recorded.
Not used: for special extensions which cannot use Caracas Desk but which
are connected, e.g. entrance telephones, service extensions for which call
detail recording is not carried out via Caracas Desk, etc.
A31003-E1320-S100-4-7620
Service Manual
Basic settings for connection to Hicom 150 E Rel. 2.2
extensions (master) on the first SLMO Hicom numbers
P0/E
Basic settings
connection, check that
0
4-9

Advertisement

Table of Contents
loading