Basic settings
Basic settings for connection to Hicom 150 E Rel. 2.2
If extensions are deleted in the process, they are not assigned an extension
number and cannot be reached! Extensions should only be deleted, there-
fore, it they are not connected.
Transfer the extension numbers back to Hicom via the Settings/Basic settings/
Write to customer data menu.
This procedure lasts 20 seconds (max. 3 minutes). Completion of the loading op-
eration is indicated by a flashing LED beside the Alarm key. The result (OK, error,
conflict) can be queried and the message deleted by pressing this key.
If conflicts arise between the extension numbers, the customer data is not trans-
ferred back to Hicom and a message regarding the conflict is output. Please note
that conflicts can also arise with codes 7..., 8..., 9... and 0 (for routes by default,
etc.). These codes can only be changed with Assistant E.
For reasons of security (old customer data), the data can only be transferred back to
Hicom within 30 minutes of loading the extension numbers to Caracas Desk.
The wake-up service is located at extension 151 (with the default extension number
600).
A name may not be set in Hicom for the configured extensions. Names are automat-
ically assigned at check-in.
Names must are also be assigned for service extensions and booths at check-in.
Names are only deleted for guests at check-out.