Bellman & Symfon Visit BE1411 Installer's Manual page 31

Hide thumbs Also See for Visit BE1411:
Table of Contents

Advertisement

VISIT RECEIVERS
Visit wrist receiver
Changing the radio key
If your Visit system is activated for no reason, there is probably a nearby system that triggers yours. In order to avoid radio
interference, you need to change the radio key on all units. The radio key switches are located on the transmitters.
Here is how you change the radio key:
1
Open the transmitter cover and move any radio key switch to the up (on position) to
change the radio key. See Changing the radio key for the relevant transmitter.
2
Press and hold the function button on the wrist receiver until the green and yellow Visit
LEDs blink alternately. Release the button.
3
Press the test button/s on the transmitter within 30 seconds to send the new radio key.
4
All Visit LEDs on the receiver blink 5 times to show that the radio key has been changed. It then returns to normal mode.
Note: All Visit units must be set to the same radio key in order to operate as a group.
1
2
Accessories
The wrist receiver can be complemented with the following accessory:
BE1270 Bed shaker
Wakes you with vibrations if anything happens while
you are asleep. Connect it to the charger and slide it
under your pillow or mattress.
Note: The bed shaker only works when the wrist receiver
is placed in the charger. The receiver will not vibrate
during charging, but the Visit LEDs will act as usual.
Press the bed shaker test button on top of the charger to
try the bed shaker vibration.
Warning! The wrist receiver and charger can ONLY USE RECHARGEABLE NiMH BATTERIES. Non-
rechargeable batteries will start to leak during charging and the battery acid will damage the electronics
in the wrist receiver and charger. The resulting damage is not covered by warranty.
59
On
Off
3
4
5
Advanced programming
By using advanced programming, you can customize the signal pattern from a specific transmitter and event, displaying
the LED color and vibration pattern of your choice. The advanced programming overrides the radio key and pairs the units
via the serial number. Please note that smoke alarms cannot be programmed for safety reasons.
Note: The transmitter must be activated as it is intended to be used in the system to generate the right signal.
This means that you can't always use the transmitter test button (see Default signal pattern for the relevant transmitter).
Here is how you program the wrist receiver:
1
Press and hold the function button on the receiver. The green and yellow Visit LEDs will start to blink alternately.
While still holding down the button, activate the desired transmitter as intended. The battery LED on the receiver lights
up in yellow to show that you are in advanced programming mode. Release the button.
2
Scroll through the different Visit LED options by pressing the function button on the receiver. Select the desired Visit
LED color by holding down the function button until the battery LED goes out and lights up again.
3
Scroll through the different vibration options by pressing the function button on the receiver. Select the desired
vibration pattern by holding down the function button until the battery LED goes out and lights up again.
4
The wrist receiver will now show the new Visit LED color and vibration pattern. Press the function button briefly to end
the demonstration. After a short while, it will return to normal mode.
Deleting the advanced programming
Follow the procedure below to delete the advanced programming.
1
Hold down the function button on the receiver until the green and yellow Visit LEDs blink alternately. Release the button.
2
Press the function button on the receiver 3 times in quick succession.
3
All Visit LEDs will light up for ~2 seconds to show that it has been deleted.
Troubleshooting
Most problems with the wrist receiver can be solved quickly by following the advice below.
If
Try this
The receiver seems to be turned off
The battery is depleted. Charge or replace it with a VARTA V40H NiMH battery.
The battery LED blinks in yellow
The battery level is low. Charge or replace it with a VARTA V40H NiMH battery.
The receiver is not charging
Check that the receiver is placed correctly in the charger and that the power supply
is connected. The mains LED and charging LED should be lit.
Charge or replace the backup batteries with four 1.2 V NiMH rechargeable batteries.
The receiver does not respond
Check the transmitter batteries and connections.
when a transmitter is activated
Move the receiver closer to the transmitter to make sure it's within radio range.
Check that the receiver is set to the same radio key as the other units in the Visit
system, see Changing the radio key.
The receiver is activated for no
There is probably another Visit system installed nearby that triggers your system.
apparent reason
Change the radio key on all units, see Changing the radio key.
The bed shaker does not vibrate
Check that the bed shaker is connected and that the receiver is placed in the charger.
BE8102
60

Advertisement

Table of Contents
loading

Table of Contents