Advertisement

XK3190-A9+
Weighing Indicator
USER' S MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XK3190-A9+ and is the answer not in the manual?

Questions and answers

Summary of Contents for Pro XK3190-A9+

  • Page 1 XK3190-A9+ Weighing Indicator USER’ S MANUAL...
  • Page 2: Table Of Contents

    X K 3 1 9 0 - A 9+ Content Chapter One Technical Parameter…………………………………………………….3 Chapter Two Installation…………………………………………………………………..5 Indicator front and back scheme……………………………………….5 Connection between Load cell and Indicator……………………..5 III. Connection between Printer and Indicator…………………………6 Connection between Scoreboard and Indicator………………….7 Connection between Serial communication interface and indicator……………………………………………………………………………..9 Chapter Three Operation…………………………………………………………………….12 Start and Start with Auto-zero……………………………………………12...
  • Page 3: Chapter One Technical Parameter

    X K 3 1 9 0 - A 9+ Chapter One Technical Parameter Model XK3190-A9+ Accuracy Class III, n=3000 Δ-Σ type of A/D Conversion -16 mV~ 18 mV Input signal range Conversion speed 10 times/second A/D resolution code 1 million code Calibration All operation made by keys Excitation power...
  • Page 4 X K 3 1 9 0 - A 9+ Transmission data format 10 bytes: 1 byte is start, 8 data bytes (ASC II code), 1 byte is stop. RS232:≤30m Transmission distance RS422/RS485:≤1200m To connect with TpuP 16 micro printer; wide line Standard parallel output printer like M800、KX-P1121、KX-P1131、LQ300K interface...
  • Page 5: Chapter Two Installation

    X K 3 1 9 0 - A 9+ Chapter Two Installation I. Indicator front and back scheme (Graph 2-1) Front View (Graph 2-2) Back View II. Connection between Load cell and Indicator 1. The 9-pin socket is used for connection with load cell, which foot definition is...
  • Page 6: Connection Between Printer And Indicator

    X K 3 1 9 0 - A 9+ shown in graph 2-3. 2. If 4-core shielded cable is used, +S must be short connected with +E, so did -S and 3. ▲!Indicator must be reliably connecting to Load cell and shielded-cable of load cell must be reliably connected to underground.
  • Page 7: Connection Between Scoreboard And Indicator

    X K 3 1 9 0 - A 9+ 2. Caution for Printing ▲!Printing function must be set in indicator before using it. ▲!Printer and Indicator’s interface must be connected by professional printer connection wire. If the connection of each foot is wrong, it will damage indicator’s output interface or printer’s input interface, or worse will be damage of indicator or printer.
  • Page 8 X K 3 1 9 0 - A 9+ (Graph 2-5 ) serial communication and scoreboard output interface 2. Scoreboard adopts current loop or RS232 by ACII code serial output, baud rate is 600. Each frame has 11 bytes of data, 1 start bit (0), 8 data bit (lower bit is in the front), 1 stop bit (1).
  • Page 9: Connection Between Serial Communication Interface And

    X K 3 1 9 0 - A 9+ First frame data:mark bit is 0 X : D0、D1、D2 – is the location of decimal ( 0~4 ) Y : D3 — is weight symbol ( 1-negative、0-positive ) D4 — back up G 18~G16: Weight (N.W.) data Second frame:mark bit is 0 G15~G8: Weight (N.W.) data...
  • Page 10 X K 3 1 9 0 - A 9+ Indicator output corresponding data according to upper monitor’s order. Each order each frame of data. Upper monitor sending order as follow: Content and note 02(XON) start A~Z address S/N A~F order A:handclasp order B:read G.W.
  • Page 11 X K 3 1 9 0 - A 9+ 14 units of data for each Order C Tare,format: frame a: symbol (+ or -) b: Tare ( 6 bits) : (from high to low) h: decimal from right to left ( 0~4) Order D N.W,format:...
  • Page 12: Chapter Three Operation

    X K 3 1 9 0 - A 9+ 00 ] Input setting password“98” Press[9][8] 98 ] Press[Input] [ Ad r ** ] Communication address ( 01~26 ) Press[1] [ Ad r 01] For example:1 Press[Input] [ b t Serial communication baud rate definition of 0~4: Press [1] [ b t...
  • Page 13: Tare Function

    X K 3 1 9 0 - A 9+ 2. when display weight deviate from ZERO, but in the range of ZERO, [ZERO] key valid, otherwise [ZERO] will be invalid, the parameter setting and setting method of ZERO range refers to calibration user’s manual. 3.
  • Page 14: Inner Code

    X K 3 1 9 0 - A 9+ positive pole, black line is negative (-) is to connect with battery negative pole. 5. if positive and negative pole is connected reversely, it will make fuse broken to protect the battery. Now, connect two poles correctly, and restart the indicator, it will work normally again.
  • Page 15: Display

    X K 3 1 9 0 - A 9+ cargo. ▲!Cargo No. must be any number from 000~200. ▲!If the TARE light is on, that means TARE weight is obtained, so one time storage will form a complete record. ▲!If the truck No. has been set as any 5-digit number over the range of 00000, and the TARE light is OFF (G.W weighing mode), then twice storage will form a complete unit of record.
  • Page 16: Record

    X K 3 1 9 0 - A 9+ (3) Stored truck No. and cargo No is the truck No. and cargo No. which has been stored before. (4) Auto storage TARE can be divided as follow three types: 1).when TARE light is on, current TARE weight will be saved to this unit of record.
  • Page 17 X K 3 1 9 0 - A 9+ Press [5] [0] [HL **] Selecting Printing Restriction Press [Input] [HL 50] 00-print only when display returns zero 25-print only when display <25% F.S. 50- Print only when display <50% F.S. 75- Print only when display <75% F.S.
  • Page 18 X K 3 1 9 0 - A 9+ sheet form. Press [5] [8] [8] [6] [tH ****] High 4 bits of Tel. setting Press [Input] [tH 5886] E.g. 5886 Press [0] [0] [0] [3] ****] Low 4 bits of Tel. setting Press [Input] 0003] E.g.
  • Page 19 X K 3 1 9 0 - A 9+ ★ Printing format refers to appendix ★ Filling printing type can use specialized non-carbon copy and printing paper to fast print in triplicate. Or specialized normal printing paper to fast print in one copy.
  • Page 20: Report Printing

    X K 3 1 9 0 - A 9+ Report printing 1. Press [print set], then press [1], press [input] to print sorted statistic daily report of current date. (That is current date’s statistic report by time order, report by truck No., report by cargo No.).
  • Page 21: How To Input Memorized Tare Weight

    X K 3 1 9 0 - A 9+ lost of DATA. ▲ !After calibration or amend printing parameter, please delete all weighing record. How to input memorized TARE weight Indicator and memorize 1000 TARE weights, input method are as follow: 1.
  • Page 22: Chapter Four Maintenance And Cautions

    X K 3 1 9 0 - A 9+ Chapter Four Maintenance and Cautions To guarantee the clarity and using life, the indicator shouldn’t be placed directly under sunshine and should be placed in the flat place. The indicator should avoid dust pollution, vibration and moisture. Load cell should connect with indicator reliably, and the system should be connected into ground properly.
  • Page 23: Chapter Five Information Indication

    X K 3 1 9 0 - A 9+ Indicator’s external interface must be used strictly according the our user’s manual. Random changing of the connection is forbidden. During the using of this indicator, if any problem happened, please unplug the power plug and send back to factory for repair. Unprofessional weighing products manufacturer is not allowed to repair it by them to prevent from more damage and loss.
  • Page 24 X K 3 1 9 0 - A 9+ 5 Err 16 Date or Time is illegal, please input right time and date. 6 Err 09 This truck No does not exist. 7 Err 10 The truck No. stored exceeds 1000. 8 Err 28 printing date is smaller than stored weighing record’s date.
  • Page 25: Appendix

    X K 3 1 9 0 - A 9+ in the calibration plug, then re-input the original calibration data, turn on the indicator again or re-calibrate it. 4 Err 22 RAM has been damaged, change the chips and re-calibration. 5 Err 23 EPROM has been damaged, change the chips and re-input the original data, re-start the indicator or re-calibration.
  • Page 26 X K 3 1 9 0 - A 9+ 1350 净重 NET 备 注 REMARK Appendix 2: report format example(applicable for printer type=2, 3) Daily report 1 Date:2008-01-01 Time Truck No. Cargo G.W.(kg) TARE (kg) N.W.(kg) 0002 12.03.24 12345 2.000 0.300 1.700 0003...
  • Page 27 X K 3 1 9 0 - A 9+ Record format: DATE 02-03-14 weight kg 0001 9 . 00 0002 9 . 00 TOTAL: 18 . 00kg Appendix 4:Printing operation examples I. One time manually pre-set TARE printing weighing bill Step Condition Operation Display...
  • Page 28 X K 3 1 9 0 - A 9+ Input new truck E.g.[00123] [o 00123] If needs original truck No. press [input] directly, no need to change. Press [input] ***] Original cargo No. input new cargo E.g. [ 11 ] 011] If needs original cargo No.
  • Page 29 X K 3 1 9 0 - A 9+ [tare] press [o *****] Needed truck No. [print] press [hn ***] Original cargo No. [input] Input new cargo No. E.g.[ 11 ] [hn 011] If the original cargo No. is corresponding, press [tare] directly, no need of inputting cargo No.
  • Page 30 X K 3 1 9 0 - A 9+ shows negative number [tare] VII. Printing weighing bill (one time stored type) step Condition operation display Note Loaded truck is press [print] [o *****] Original truck No. on platform (wait for stable light is on) Input new truck...

Table of Contents

Save PDF