Inner Code - Pro XK3190-A9+ User Manual

Weighing indicator
Table of Contents

Advertisement

positive pole, black line is negative (-) is to connect with battery negative pole.
5. if positive and negative pole is connected reversely, it will make fuse broken to
protect the battery. Now, connect two poles correctly, and restart the indicator,
it will work normally again.
Battery is consuming products, not in the range of guarantee.
VI.
Inner code display
1. In weighing mode, press [print set], then input [2], [8], indicator will enter into
inner code display mode, and inner code light is ON. Press [print set], input [2], [8],
indicator will exit inner code display mode; inner code light will be off.
2. In inner code display mode, only [ZERO], [Print set] key is available, other keys are
all unavailable.
3. 20 inner code equals 1 division, E.g. while n=3000, the full scale's inner code is
60000 code.
VII. Saving for Data record
1. Indicator regulates that truck No. should be 5 digits, cargo No. is 3 digits. The
maximum storage is 1000pcs of truck No., 201pcs of cargo No.
2. Every complete unit of weighing record is stored; indicator will print out this unit
of data. (if printing setting is valid)
3. Data storage has follow 3 methods:
(1) Store empty truck, then full truck store; or store full truck store then empty
truck store. That is to say, twice storage consists of a complete unit of record.
(2) Full truck for weighing and TARE has been obtained, one time storage will
form a unit of complete record.
(3) The weight object is a kind of cargo, not a truck, then one time storage will
form a unit of complete record for always.
In order to automatically recognize the above three types of storage, XK3190-A9+
makes following special agreement.
▲!Truck No. must be any number from 00001~99999, that is 00000 can not be a
real truck number. If truck No. has been set as 00000, that means it is not a truck but a
X K 3 1 9 0 - A 9+
14

Advertisement

Table of Contents
loading

Table of Contents