Reading Out Via Serial Interface - Novexx Solutions AP 4.4 Service Manual

Hide thumbs Also See for AP 4.4:
Table of Contents

Advertisement

04/09 Rev. 5.01-02

Reading out via serial interface

Prerequisites
Firmware (at least):
Version
Printing device
3.22
AP 4.4 (16 MB), AP 5.4, AP 7.t
4.22
64-xx Gen. 2, DPM, ALX 92x
5.02
64-xx Gen. 3, PEM
Terminal program, e. g. „Hyperterminal" (is
delivered with Windows operating sys-
tems).
Carrying out
1. Connect the printing device to a PC, using
the serial interface. Set the transfer param-
eters to 115 kB, n, 8, 1 (default setting).
2. Start Hyperterminal.
The window „Connection Description" [1]
opens.
3. Name the new connection [1A]. Click OK.
The window „Connect" opens.
4. Select the serial port of the PC and click
OK.
The window „COM1 Properties" [2] opens (if
COM1 was selected).
5. Set the transfer parameters to
115 kB, n, 8, 1 and click OK.
The Hyperterminal main window opens.
6. Open the menu „Transfer" and click
„Record Text" [3]. An input window opens.
Enter the file name for the record file and
click „Start".
7. At the printer operation panel press all four
buttons simultaneously.
This starts data being read out of the print-
ing device and being displayed in the
Hyperterminal main window [4]. At the
same time, the data are saved in the record
file.
8. To stop the transmission, click „Cancel" in
the menu „Transfer > Record text...".
Generating further record files:
Close Hyperterminal and start new.
SERVICE MANUAL
AP 4.4 – AP 5.4 – AP 7.t
[1] Enter a name (A) for the new connection.
[2] Set the transfer parameters.
[3] Hyperterminal main window.
8