eDP0_HPD: Hot Plug Detect, Active high Input signal of +1.8V_RUN electrical level from carrier board. 1MΩ pull-down resistor is placed on module for this signal.
Please refer to the following schematics as an example of connection of eDP interface on the carrier board. Hot Plug Detect signal must be buffered to prevent back
feeding of power from the display to the module as well as level translation.
The signals for Channel #1 of the LVDS interface is always available on the edge pinout regardless of the factory board configuration.