APPENDICES
Number
Name
Data memory
M9016
clear flag
Data memory
M9017
clear flag
2
Data link monitor
M9018
switching
User timing clock
M9020
No. 0
User timing clock
M9021
No. 1
User timing clock
M9022
No. 2
User timing clock
M9023
No. 3
User timing clock
M9024
No. 4
2
Clock data set
M9025
request
M9026
Clock data error
Clock data
M9027
display
2
Clock data read
M9028
request
Data
2
communication
M9029
request batch
process
Table 2.1
Special relay list (Continue)
Description
• Clears the data memory including the latch range
OFF: No processing
(other than special relays and special registers) in
ON: Output clear
remote run mode from computer, etc. when M9016 is
on.
• Clears the unlatched data memory (other than
OFF: No processing
special relays and special registers) in remote run
ON: Output clear
mode from computer, etc. when M9017 is on.
OFF: F link
• Specifies the lines to be monitored for link
ON: R link
monitoring.
• Relay that repeats on/off at intervals of
predetermined scan.
• When power is turned on or reset is per-formed, the
n2
n2
clock starts with off.
scan
scan
• Set the intervals of on/off by DUTY instruction.
n1
scan
• Writes clock data from D9025-D9028 to the clock
element after the END instruction is executed
OFF: No processing
ON: Set requested
during the scan in which M9025 has changed from
off to on.
OFF: No error
• Switched on by clock data (D9025 to D9028) error
ON: Error
and switched off without an error.
OFF: No processing
• Clock data such as month, day, hour, minute and
ON: Display
minute are indicated on the CPU front LED display.
OFF: No processing
• Reads clock data to D9025-D9028 in BCD when
ON: Read request
M9028 is on.
• Turn M9029 on in the sequence program to process
all data communication requests, which have been
received in the entire scan, during END process of
the scan.
OFF: No batch process
• The data communication request batch process can
ON: Batch process
be turned on or off during operation.
• OFF in default state (Each data communication
request is processed at the END process in the order
of reception.)
Details
DUTY
n1
APP - 7
MELSEC-A
Applicable CPU
Usable with all
types of CPUs.
Usable with all
types of CPUs.
Dedicated to A3V.
Usable with all
types of CPUs.
n2
M9020
Unusable with An,
A3H, A3M, A3V,
A2C and A0J2H.
Unusable with An,
A3H, A3M, A3V,
A2C and A0J2H.
Usable with A3N,
A3A, A3U, A4U,
A73 and A3N
board.
Unusable with
An, A3H, A3M,
A3V, A2C and
A0J2H.
Usable with AnU
and A2US(H).

Hide quick links: