FE2owlet-ECQ
Motor size U
EC-fans with top efficiency
Assembly instructions
Keep for reference!
L-BAL-F062-GB 2022/20 Index 004
Part.-No. 00702389-GB

Advertisement

Table of Contents
loading

Summary of Contents for ZIEHL-ABEGG FE2owlet-ECQ

  • Page 1 FE2owlet-ECQ Motor size U EC-fans with top efficiency Assembly instructions Keep for reference! L-BAL-F062-GB 2022/20 Index 004 Part.-No. 00702389-GB...
  • Page 2: Table Of Contents

    Assembly instructions FE2owlet-ECQ Content General notes ..........
  • Page 3 Assembly instructions FE2owlet-ECQ Diagnostics / Faults ........
  • Page 4: General Notes

    Assembly instructions FE2owlet-ECQ General notes 1 General notes Compliance with the following specifications also serves to ensure product safety. Should the specified information, in particular with regard to general safety, transporta- tion, storage, assembly, operating conditions, commissioning, service, maintenance, cleaning and disposal/recycling not be observed, safe operation of the product may not be guaranteed and can potentially pose a risk of death or injury to users and/or third parties.
  • Page 5: Copyright

    Assembly instructions FE2owlet-ECQ Safety instructions ZIEHL-ABEGG SE is not liable for damage due to misuse, improper use or as a consequence of unauthorized repairs or modifications. 1.5 Copyright These assembly instructions contain copyright protected information. The assembly instructions may be neither completely nor partially photocopied, reproduced, translated or put on data medium without previous explicit consent from ZIEHL-ABEGG SE.
  • Page 6: Explanations Of Symbols

    Assembly instructions FE2owlet-ECQ Safety instructions • Use of the fan as an independent household appliance. • Use as a fire gas or smoke extraction fan (special application according to DIN EN 12101-3). • Use with vibration loading by customer device. Resonant operation and operation with severe vibrations or oscillation.
  • Page 7: Requirements Placed On The Personnel / Due Diligence

    Assembly instructions FE2owlet-ECQ Safety instructions 2.5 Requirements placed on the personnel / due diligence Persons entrusted with the planning, installation, commissioning and maintenance and servicing in connection with the frequency inverter must have the corresponding qual- ifications and skills for these jobs.
  • Page 8: Operator's Obligation Of Diligence

    ZIEHL-ABEGG.These parts were specifically designed for the device. There is no guarantee that parts from non-original sources are designed and manufactured in correspondence with load and safety requirements. Parts and optional equipment not supplied by ZIEHL-ABEGG are not approved by ZIEHL-ABEGG for use. 2.8 Operator’s obligation of diligence •...
  • Page 9: Product Overview

    3.4 Note on the ErP directive ZIEHL-ABEGG SE wishes to point out that, based on the directive (EU) no. 327/2011 of the Commission of 30th of March 2011 for enforcing directive 2009/125/EC (hereinafter referred to as ErP directive), the operational area of certain fans within the EU is bound by certain prerequisites.
  • Page 10: Transport, Storage

    All ErP-relevant information comprises measurements which are determined using a standardised measurement set-up. More details can be obtained from the manufacturer. Further information about the ErP directive (Energy related Products-Directive) can be found on www.ziehl-abegg.de search key: "ErP". 3.5 Transport, storage Attention! •...
  • Page 11: Mounting

    Assembly instructions FE2owlet-ECQ Mounting 4 Mounting 4.1 General notes Attention! • Check the fan for damage, e.g. cracks, dents or damage to the electric cables, before assembly. Start-up is not allowed in the case of transport damage! • Mounting is only to be undertaken by trained service personnel. The system...
  • Page 12: Dimensions Motor

    Assembly instructions FE2owlet-ECQ Mounting 4.3 Dimensions motor 03060-NN04 17.11.2021 Info The 7 holes in the motor's plastic housing (for self-tapping screws Ø 4.2) are designed for one-time use. 4.4 Mounting fans design A and E To attach the fan unit, use screws with a property class of 4.8 as per EN ISO 4014 and provide with suitable thread lockers.
  • Page 13: Connection Of The Motor

    Assembly instructions FE2owlet-ECQ Mounting Info • Every screwing case is different. The tightening torque adapted to it must be determined by the appropriate screw tests. • Avoid structural damage or stress with installation. Make sure the surface is flat and even.
  • Page 14 Assembly instructions FE2owlet-ECQ Mounting Connection diagram for motors with three speeds If the black wire is connected with the brown wire, the motor runs at speed step 3 rpm 3 rpm 2 If the black wire is connected with the blue wire,...
  • Page 15: Commissioning

    3. Check the system for resonances. If they lead to unacceptably high vibrations on the fan, the system must not be started up. 4. Fans from ZIEHL-ABEGG SE are delivered balanced in accordance with DIN ISO 21940-11 for the appropriate fan category in accordance with ISO 14694.
  • Page 16: Diagnostics / Faults

    Assembly instructions FE2owlet-ECQ Diagnostics / Faults 6 Diagnostics / Faults 6.1 Trouble shooting Type of error Possible cause Remedial measures Fan does not Mains voltage failure Check mains voltage run (anymore) Failure of a phase Under - or overvoltage Coil closure...
  • Page 17: Service Work

    Repair, e.g. by welding or gluing is prohibited! • Bolted-on or pressed on impellers and/or wings may only be replaced by authorised ZIEHL-ABEGG SE staff. The manufacturer shall not be liable for damage caused through improper repair work. • Regular inspection and possibly cleaning is necessary to prevent imbalance and blockage of the drain holes due to ingress of dirt.
  • Page 18: Cleaning

    Assembly instructions FE2owlet-ECQ Enclosure 7.2 Cleaning Danger due to electric current • Voltage supply for motor must be interrupted and secured against restoration! • Do not use any aggressive cleaning agents when cleaning. • Make sure that no water gets into the inside of the motor and electronics.
  • Page 19 Assembly instructions FE2owlet-ECQ Enclosure For motors with one speed and corresponding quality mark rating plate) Authorization: FILE No. UL 1004-7 E347018 Electronically-Protected Motor - Component For motors with three speeds and corresponding quality mark rating plate) Authorization: FILE No. UL 1004-3...
  • Page 20: Ec Declaration Of Incorporation

    Assembly instructions FE2owlet-ECQ Enclosure EC Declaration of Incorporation - Translation - (english) ZA87-GB 2022/17 Index 012 as defined by the EC Machinery Directive 2006/42/EC, Annex II B The design of the partly completed machine: Axial fan DN.., FA.., FB.., FC.., FE.., FF.., FG.., FH.., FL.., FN.., FP.., FS.., FT.., FV.., VN.., VR.., ZC.., ZF.., ZG.., ZN..Centrifugal fan ER.., GR.., HR.., RA.., RD.., RE.., RF..,...
  • Page 21 Assembly instructions FE2owlet-ECQ Enclosure The following persons are authorized to compile the technical documents, address see above. Upon reasonable request, the special documents shall be transmitted to the public authority. The transfer can be made electronically, on data carriers or on paper. All property rights remain with the aforementioned manufacturer.
  • Page 22: Ukca Declaration Of Incorporation

    Assembly instructions FE2owlet-ECQ Enclosure UKCA Declaration of - Original - (english) Incorporation ZA87_UK-GB 2022/17 Index 002 as defined by the Supply of Machinery (Safety) Regulations 2008 No. 1597, PART 2 / Annex II B The design of the incomplete machine: Axial fan DN.., FA.., FB.., FC.., FE.., FF.., FG.., FH.., FL.., FN.., FP.., FS.., FT.., FV..,...
  • Page 23 Assembly instructions FE2owlet-ECQ Enclosure The following persons are authorized to compile the technical documents, address see above. The specific documentation will be transmitted to the official authorities on justified request. The transmission can be electronic, on data carriers or on paper. All industrial property rights remain with the above-mentioned manufacturer.
  • Page 24: Manufacturer

    If you have any questions about how to use our products or if you are planning special applications, please contact: ZIEHL-ABEGG SE Heinz-Ziehl-Straße D-74653 Künzelsau Phone 07940/16-0 Fax 07940/16-300 info@ziehl-abegg.de 8.5 Service address Please refer to the homepage at www.ziehl-abegg.com for a list of our subsidiaries worldwide. L-BAL-F062-GB 2022/20 Index 004 Part.-No. 00702389-GB 24/24...