Download Print this page

M-system 61F Instruction Manual

Analog i/o module

Advertisement

Quick Links

INSTRUCTION MANUAL
ANALOG I/O MODULE
(Fuji Electric T-Link use)
BEFORE USE
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Analog I/O module (body + base socket) ............................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL
POINTS OF CAUTION
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
85 – 132V AC rating: 85 – 132V, 47 – 66 Hz, approx. 3VA
24V DC rating: 24V ±10%, approx. 4W, approx. 160mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply, input signal and output signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: MxBS2).
61F
EM-6635 Rev.2 P. 1 / 3

Advertisement

loading

Summary of Contents for M-system 61F

  • Page 1 (Fuji Electric T-Link use) BEFORE USE POINTS OF CAUTION Thank you for choosing M-System. Before use, please check ■ POWER INPUT RATING & OPERATIONAL RANGE contents of the package you received as outlined below. • Locate the power input rating marked on the product and...
  • Page 2 Blinking during normal I/O function L COM (red) Blinking during normal T-Link Communication Euro type connec- For wiring to T-Link tor terminal for T-Link EM-6635 Rev.2 P. 2 / 3 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 3 Note: Use terminals T1, T2 and SD for cross-wiring. WIRING INSTRUCTIONS LIGHTNING SURGE PROTECTION ■ EURO TYPE CONNECTOR TERMINAL (T-Link) M-System offers a series of lightning surge protectors for protection against induced lightning surges. Please contact Applicable wire size: 0.2 to 2.5 mm (AWG24 to 12) M-System to choose appropriate models.