M-system R7L-DA16 Instruction Manual

Discrete input module, 16 points (lonworks)
Hide thumbs Also See for R7L-DA16:

Advertisement

Quick Links

INSTRUCTION MANUAL
DISCRETE INPUT MODULE, 16 points
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Discrete input module .........................................................(1)
NeuronID label ....................................................................(2)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
LNS Plug-in Software (model: R7LPLG) is usable to set up
Functional Blocks. For detailed information, refer to the
R7PLG Users Manual. The R7LPLG is downloadable at M-
System's web site: http://www.m-system.co.jp
(L
W
)
ON
ORKS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL
POINTS OF CAUTION
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V AC rating: 24V ±10%, 50/60 Hz, approx. 70mA
24V DC rating: 24V ±10%, approx. 40mA
■ GENERAL PRECAUTIONS
• The unit can acquire 16 points of discrete input, also
pulse input can be acquired up to 8 points out of 16 points.
• When counter pulse and discrete are mixed and acquired,
make sufficient consideration to them.
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ RESTRICTIONS WHEN USING LonMaker3.0 or 3.1
• Operating Environment
Please use LonMaker3.0 under the Environment of LNS3
Service Pack 8 and use LonMaker3.1 under the Environ-
ment of LonMaker3.1 Service Pack 3 or later.
Please use resource files of LonMark Resource File Ver12
or later.
• LNS Plug-in Software is not usable.
• The network variable of nvoCNTOut (fbCNT) is only
SNVT_count_f.
• When registering a Device on LonMaker, please don't use
the following items.
External Interface Definition / Upload From Device
Specify Device Channel / Auto-Detect
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
R7L-DA16
EM-7804-F Rev.10 P. 1 / 19

Advertisement

Table of Contents
loading

Summary of Contents for M-system R7L-DA16

  • Page 1 ORKS BEFORE USE ..POINTS OF CAUTION Thank you for choosing M-System. Before use, please check ■ POWER INPUT RATING & OPERATIONAL RANGE contents of the package you received as outlined below. • Locate the power input rating marked on the product and...
  • Page 2: Component Identification

    Used to reset the Neuron Chip. Press the switch behind the front cover to reset. Control functions are halted while completing resetting and restarting. Confirm no danger before conducting resetting. EM-7804-F Rev.10 P. 2 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 3: Terminal Connections

    ■ CONNECTION DIAGRAM Input Connection Examples ORKS NET1 PNP Connection NPN Connection NET1 – – + ORKS NET2 NET2 U (+) V (–) EM-7804-F Rev.10 P. 3 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 4: Communication Cable Connections

    Applicable wire size: 0.25 to 1.65 mm (AWG 22 to 16) Recommended manufacturer: Japan Solderless Terminal MFG. Co., Ltd, Nichifu Co., Ltd 3.3 (.13) max mm (inch) EM-7804-F Rev.10 P. 4 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 5: Functional Blocks

    Device Interface File (XIF) is used to define a L device when programmed on LonMaker. ORKS For this module, the following file is used: R7L-DA16v113.XIF The XIF files are downloadable at M-System’s web site: http://www.m-system.co.jp FUNCTIONAL BLOCKS ■ NodeObject NodeObject (Object ID : 0) Network Variables...
  • Page 6 {SNVT_str_asc} SCPToemType ---- Used to indicate Model No. and Version {e.g. “R7L-DA16_VER:0.10”} {SNVT_str_asc} SCPTserialNumber ---- Used to indicate Serial No. {e.g. “ZZ123456”} EM-7804-F Rev.10 P. 6 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 7 {0...999 999 999} Number of ON counts or accumulated time of ON status at nviCNTIn or nvoCNTOut {SNVT_count_f} the input terminal {0...999 999} EM-7804-F Rev.10 P. 7 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 8 Set value applied at nvoCNTOut when fbCNT[ ] is Over- SCPTsetpoint nvoCNTOut Default = Max. range value Ride. available for the type EM-7804-F Rev.10 P. 8 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 9 EM-7804-F Rev.10 P. 9 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 10 {ST_OFF, ST_ON} ST_OFF : OFF at open contact, ON at closed contact {ST_OFF} ST_ON : ON at open contact, OFF at closed contact EM-7804-F Rev.10 P. 10 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 11 SCPTtimeout ---- {0.1...60.0} OFF is immediately output when nviCMPIn1 and nviC- {5.0} MPIn2 states match, regardless of this setting. EM-7804-F Rev.10 P. 11 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 12 {0.0 0} {SNVT_switch} Outputs the SCPTvalueDefinition[ ] value according to the input signal nvoENOut {0.0 0}, {100.0 1}, {Invalid} status {0.0 0} EM-7804-F Rev.10 P. 12 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 13 SCPTvalueDefinition[1] SCPTvalueDefinition[2] SCPTvalueDefinition[3] SCPTvalueDefinition[4] SCPTvalueDefinition[5] SCPTvalueDefinition[6] SCPTvalueDefinition[7] SCPTvalueDefinition[8] SCPTvalueDefinition[9] SCPTvalueDefinition[10] SCPTvalueDefinition[11] SCPTvalueDefinition[12] SCPTvalueDefinition[13] SCPTvalueDefinition[14] SCPTvalueDefinition[15] Invalid in one or more nviENIn SCPTvalueDefinition[16] EM-7804-F Rev.10 P. 13 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 14 ON, nvoTMROut = OFF in any other conditions. {ST_OFF} ST_ON : nvoTMROut = OFF with the timer functioning and ON, nvoTMROut = ON in any other conditions. EM-7804-F Rev.10 P. 14 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 15 Defines ON-OFF time period. ON and OFF times are equal. SCPTtimeout[1] ---- {0.0...800.0} One pulse cycle equals twice as long as the set value. {0.0} {SNVT_time_sec} SCPTtimeout[2] ---- {0.0} Invalid {0.0} EM-7804-F Rev.10 P. 15 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 16 EM-7804-F Rev.10 P. 16 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 17 {SNVT_switch} {0.0 0}, {100.0 1}, Set value applied at nviDOEX2 when the power supply is SCPTpwrUpState nviDOEX2 {Invalid} turned on. {0.0 0} EM-7804-F Rev.10 P. 17 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 18 EM-7804-F Rev.10 P. 18 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 19 {ST_OFF, ST_ON} ST_OFF : OFF at open contact, ON at closed contact {ST_OFF} ST_ON : ON at open contact, OFF at closed contact EM-7804-F Rev.10 P. 19 / 19 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...