Description
Frequency band - ERP
Range Line of sight (guaranteed)
AC power supply
DC power supply
Antenna
Removable EEPROM
Signaling
STOP Outputs (400-900MHz)
Start Relay
Safety Relay
ON/OFF outputs
Proportional Outputs
CAN Bus Protocols
ON/OFF inputs
Analog inputs
Response Time
Maximum Total output current
Operating Temperature Range
Storage Temperature Range (24h)
Storage Temperature Range (long periods)
Relative Humidity
Weight
Dimensions (LxWxH mm)
Tether connection
Associated transmitters (400-900MHz)
Options
Inputs
8 |
©
Danfoss | March 2019
Value
433.050 to 434.040 MHz; ERP<1mW
434.040 to 434.790 MHz; ERP<10mW
869.700 to 870.000 MHz; ERP<5mW
902.000 to 928.000 MHz; ERP<1mW
100m
48 - 230 Vac ±25% (Multivoltage) / 18-30 Vac (700mA)
8 - 36 Vdc (2A)
Internal
Internal
External
1 (6A)
1 (6A)
1 (6A)
6 (6A)
N/A
CANopen
Option
Option
100ms
8A
-20 °C to 70 °C (-4 °F to 158 °F)
-25ºC to 75ºC (-13ºF to 167ºF)
-25ºC to 55ºC (-13ºF to 131ºF)
max. 95% without condensation
640 grams
151x129x61
N/A
Ikargo1, T70/1, T70/2, IK2
4 Digital or 1 Proportional input board