    7.2 Frequency Conversion Board Fault Table ..................14 8. Appendix ..............................15 8.1 Wiring Diagrams..........................15 8.2 Parameter List ........................... 17 8.3 Cable Specifications .......................... 17 9. Maintenance ............................18 9.1 F.A.Q ..............................18 9.2 Advanced ............................19 10. Warranty ............................... 22 info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 3: Introduction

    The data above is based on the Evo heat pump only, it does not include auxiliary devices. Product specification information provided above is correct at the date of printing, this data may change without notice. Please speak with an EvoHeat Specialist for the most current product specifications.
  • Page 4: Dimensions

    Page 3 Advanced DHP-R Manual 2. Dimensions DHP20-R, DHP30-R, DHP40-R & DHP50-R DHP-R A (L) B (W) C (H) 20 & 30 40 & 50 DHP603-R DHP-R A (L) B (W) C (H) 603-R 1015 1130 info@evoheat.com.au 1300 859 933...
  • Page 5: Quick Start Guide

    1. Attach the supplied barrel unions to the cold inlet and hot outlet (hand tighten). 2. Us p mb h ‘O’ byp ss by c “T” p c 3. Install a 3-way valve at the cold-w 4. Make the plumbing connections and brace pipework where necessary. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 6 NOTE: The water pump must be running and water circulating through the heat pump for the system to operate. 1. Turn on your water filter pump and check for water leaks and verify flow to and from the pool. 2. Turn on the electrical power supply to the EvoHeat unit. 3. Press the ON/OFF button of the controller for half a second, the heat pump will start within 60 seconds 4.
  • Page 7: Safety Instructions

    Do not use any means to accelerate the defrosting processor or to clean The unit is equipped with other than those recommended by EvoHeat. an over-load protection The unit must be stored in a room without any continuously operating system.
  • Page 8: Installation

    5.1 System Installation Upon receiving the unit, check the packaging for any obvious signs of damage. Inform EvoHeat immediately if there is any evidence of rough handling. When the heater has been removed from the packaging check the refrigerant gauge on the front panel of the unit.
  • Page 9: Airflow Clearances

    5.4 Adequate Water Flow All EvoHeat heat pumps have a factory pre-set internal water flow switch. If there is insufficient water flow the unit will not operate. It is VITAL that that there is sufficient water flow to the unit. Incorrect water flow can cause a loss of efficiency and possible damage to the unit.
  • Page 10: Plumbing

    Correct phase connection is important with 3 phase heaters. NOTE: if 2 lights are showing on the 3 PHASE relay monitor this means the EvoHeat heat pump has been wired correctly (one orange light and one green light). If only one light is showing, the phases are out of rotation and need to be rotated to get the correct phase rotation.
  • Page 11: Operation

    LOCK Lock or unlock the screen. 6.2 Operating Functions EvoHeat have developed a YouTube Channel with video walkthroughs of the different controller functions. Scan the QR code or head to our channel to view the videos we have available https://www.youtube.com/evoheat 6.2.1 Startup &...
  • Page 12: Clock Settings

    . C ck ‘OFF’ ff h the range of 0:00 – 23:00; the value can be manually, however the unit will turn off this setting once it reaches the end time. precise to the hour digit. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 13: Fault History

    The temperature curve automatically updates every hour and will be stored for 60 days. If the unit is powered off after less than 1 hour of operation, the data in this period will not be saved. info@evoheat.com.au 1300 859 933...
  • Page 14: Troubleshooting

    2. Check the wire connection and make sure they motor module and fan motor is in bad are in good contact. contact Communication Fault (speed Speed control module and main board E081 Check the communication connection control module) communication fail info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 15: Frequency Conversion Board Fault Table

    Check and adjust the current measurement EEPROM Error Warn MCU error Check whether the chip is damaged Replace the chip V15V over/undervoltage The V15C is overload or undervoltage Check the V15V input voltage in range 13.5v~16.5v or not fault info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 16: Appendix

    Remote OT :Outlet water temperature AT CT OT HP LP ON/ OFF PH:Pan heater WIFI Controller SUT :Suction temperature 4V:4 way valve DHP20-R BRN BLU Y/ G TO PUMP RLY1 485B1 485A1 TO POWER PC1002 SUPPLY 220 -240 V~/50Hz 485B2 AT:Ambient temperature...
  • Page 17 KS:Relay of compressor start LP: Low pressure protection :Mechanism temperature switch Remote OT Outlet water temperature : PH:Pan heater AT CT OT IT SUT HP LP ON/OFF TC:Transformer SUT: Suctiontemperature 4V: 4 way valve DHP50-R info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 18: Parameter List

    2 x 35mm 3 x 35mm 35mm 160A 123~148A 2 x 50mm 3 x 50mm 50mm 225A 148~186A 2 x 70mm 3 x 70mm 70mm 250A 186~224A 2 x 95mm 3 x 95mm 95mm 280A info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 19: Maintenance

    9. Maintenance 9.1 F.A.Q It is recommended that you get your EvoHeat unit serviced once a year by your local certified air conditioning or refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary.
  • Page 20: Advanced

    Prior to recharging the system, it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. The safety wire model is 5*20_5A/250VAC, and must meet the explosion-proof requirements. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 21 (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 22 Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
  • Page 23: Warranty

    REGISTER YOUR WARRANTY EvoHeat highly recommend customers complete their warranty details online to ensure efficient warranty claim processing. To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/...

This manual is also suitable for:

Dhp30-rDhp40-rDhp50-rDhp603-r

Table of Contents