    EvoHeat Fusion-i Series Manual Contents 1. Introduction _____________________________________________________________________________________ 2 2. Unit Dimensions _________________________________________________________________________________ 3 3. Quick Start Guide _________________________________________________________________________________ 5 4. Safety Instructions ________________________________________________________________________________ 7 5. Installation ______________________________________________________________________________________ 8 5.1 System Installation ____________________________________________________________________________ 8 5.2 Heater Condition ______________________________________________________________________________ 8 5.3 Location Recommendations _____________________________________________________________________ 9 5.4 Airflow Clearances _____________________________________________________________________________ 9...
  • Page 3: Introduction

    EvoHeat Fusion-i Series Manual 1. Introduction This manual contains all the necessary information in regard to the installation, troubleshooting, operation and maintenance of this unit. Ensure instructions in this manual are adhered to at all times. Failing to comply with these recommendations will invalidate the warranty.
  • Page 4: Unit Dimensions

    EvoHeat Fusion-i Series Manual 2. Unit Dimensions Unit: mm Fusion-i 7, 9 & 12...
  • Page 5 EvoHeat Fusion-i Series Manual Fusion-i 16 Fusion-i 19...
  • Page 6: Quick Start Guide

    EvoHeat Fusion-i Series Manual 3. Quick Start Guide IMPORTANT THINGS TO NOTE • Ensure you meet the minimum clearances and recommended installation locations as outlined in the manual. • All heat pump accessories are contained in a plastic bag inside the packaging of your heat pump unit.
  • Page 7 1. Turn on your water filter pump and check for water leaks and verify flow to and from the pool. 2. Turn on the electrical power supply to the EvoHeat unit. 3. Press the ON/OFF button of the controller for half a second, the heat pump will start within 60 seconds 4.
  • Page 8: Safety Instructions

    EvoHeat Fusion-i Series Manual 4. Safety Instructions Installation, repair or relocations must be done by a fully qualified person and not by the customer. If done incorrectly it may cause fire, electric shock, water leakage and other hazards. A circuit breaker must be installed for the unit.
  • Page 9: Installation

    The schematic diagram is for reference only. Please check the water inlet/outlet label on the heat pump while plumbing the unit. IMPORTANT: EvoHeat heat pumps MUST be connected by a licensed electrician. Under no circumstances should an unlicensed person attempt to install or repair an EvoHeat heat pump themselves. Heater electrical installation undertaken by an unlicensed installer will void the warranty.
  • Page 10: Location Recommendations

    If you do not have a location with these suggested clearances, please contact our EvoHeat Tech Support Specialist to discuss appropriate installation locations.
  • Page 11: Adequate Water Flow

    It is CRITICAL that there is sufficient water flow to the unit. Incorrect water flow can cause a loss of efficiency and possible damage to the unit. Optimal water flow rates are listed in the EvoHeat manual. It is imperative that water flow is kept as close as possible to these flow rates.
  • Page 12: Plumbing

    EvoHeat Fusion-i Series Manual 5.9 Plumbing The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger requires no special plumbing arrangements except bypass (please set the flow rate according to the nameplate). The water pressure drop is less than 10kPa at max.
  • Page 13: Operation

    EvoHeat Fusion-i Series Manual 6. Operation 6.1 Main Controller Interface Icon Name Function MUTE Under heating or auto mode, the mute operation can be applied or removed. MODE Switch unit mode, temperature setting and parameter setting. ON/OFF Start-up/shutdown unit OR Cancel current operation and return to last level of operation...
  • Page 14: Functions Of The Controller

    EvoHeat Fusion-i Series Manual 6.2 Functions of the Controller 6.2.1 Start-up & Shutdown Only from the main screen, the unit can be turned on of off. If the half or full-off screen appears, press any key to go back to the main interface.
  • Page 15: System Time Settings

    EvoHeat Fusion-i Series Manual 6.2.4 System Time Settings Hold the CLOCK button for 2 seconds to enter the system time setting interface. Press the CLOCK again to adjust the time. After the first press, the hour parameter will be flashing which means it can be changed, use the UP & DOWN arrow accordingly.
  • Page 16: Silent Settings

    EvoHeat Fusion-i Series Manual 6.2.5.2 Cancelling a Timer Select ON1, OFF1, ON2 or OFF2 to cancel the corresponding timer. To cancel a timer, while the hour value is selected and flashing, press the ON/OFF button to clear it. Then press the ON/OFF button again to save and return to the main button.
  • Page 17: Keyboard Lock

    EvoHeat Fusion-i Series Manual When the MUTE icon is lit, the timing silent has been set but is not yet under silent status. When the MUTE icon is flashing, it is under silent status. When there is no MUTE icon, the timing silent has not been set.
  • Page 18: Troubleshooting

    7. Troubleshooting EvoHeat have developed a YouTube Channel where you will find useful videos - from setting up your timers to setting up the EvoHeat app. View it to see resolutions to some of our most asked, yet easily solved questions: https://www.youtube.com/channel/UCfYiOxHuybBuC1NZcqUnrcA/videos...
  • Page 19: Frequency Conversion Board Fault Table

    EvoHeat Fusion-i Series Manual 7.2 Frequency Conversion Board Fault Table Protection/Fault Fault Reason Elimination Methods Display Drv1 MOP alarm MOP drive alarm Recovery after the 150s Inverter offline Frequency conversion board and main board Check the communication connection communication failure...
  • Page 20: Appendix

    EvoHeat Fusion-i Series Manual 8. Appendix 8.1 Interface Drawings (1) Main Board – Fusion i7/ Fusion i9/ Fusion i12...
  • Page 21 EvoHeat Fusion-i Series Manual (2) Main board – Fusion i16/ Fusion i19...
  • Page 22: Parameter List

    EvoHeat Fusion-i Series Manual Number Sign Meaning P10-(U) Compressor (output 220-230VAC) P10-(V) P10-(W) CN18 Water pump (output 220-230VAC) (EMV) CN13 4-way valve (output 220-230VAC) (HEAT) CN96 (H) High speed of fan (output 220-230VAC) CN96 (L) Low speed of fan (output 220-230VAC)
  • Page 23: Comparison Table Of Refrigerant Saturation Temperature

    EvoHeat Fusion-i Series Manual Three Phase Unit Nameplate maximum Phase line Earth line Creepage Protector Signal Line current No more than 10A 2 x 1.5mm 1.5mm 10~16A 2 x 2.5mm 2.5mm 16~25A 2 x 4mm 25~32A 2 x 6mm 32~40A...
  • Page 24: Maintenance

    Do I need to get my unit serviced? It is recommended that you get your EvoHeat unit serviced once a year by your local certified air conditioning or refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary.
  • Page 25 EvoHeat Fusion-i Series Manual CHECKS TO THE AREA Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
  • Page 26 EvoHeat Fusion-i Series Manual CHECKS TO ELECTRICAL DEVICES Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
  • Page 27 EvoHeat Fusion-i Series Manual LEAK DETECTION METHODS The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
  • Page 28 EvoHeat Fusion-i Series Manual The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order.
  • Page 29: Warranty

    10.1 Warranty Registration EvoHeat highly recommend customers to complete their warranty details online to ensure efficient warranty claim processing. To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/...