CONTENTS 1. Preface 2. Specifications 2.2 Dimensions for Swimming Pool Heat Pump Unit 3. Installation and Connection 3.1 Installation of System 3.2 Swimming Pool Heat Pumps Location 3.3 How Close to Your Pool? 3.4 Swimming Pool Heat Pumps Plumbing 3.5 Swimming Pool Heat Pumps Electrical Wiring 3.6 Initial Start-up of the Unit 4.
1. PREFACE In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacture of this product will not be held responsible if someone is injured or the unit is damaged, as a result of improper installation, debugging, or unnecessary maintenance.
2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit Models :CS57 Water outlet φ60.3 Drainage Water inlet φ32 φ60.3 1490 Horizontal vision 1464 Vertical vision...
3.INSTALLATION AND CONNECTION 3.1 Installation illustration Valve Chlorinator cell Water outlet Water supply Pool Water inlet Sand filter Water pump (or other type filter) Installation items: The factory only provides the main unit and the water unit; the other items in the illustration are necessary spare parts for the water system ,that provided by users or the installer.
3.INSTALLATION AND CONNECTION 3.2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided that the following three factors are presented: 1. Fresh Air - 2. Electricity - 3. Pool filter piping The unit may be installed virtually anywhere outdoors. For indoor pools please consult the supplier.
3.INSTALLATION AND CONNECTION 3.4 Swimming Pool Heat Pumps Plumbing The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger requires no special plumbing arrangements except bypass(please set the flow rate according to the nameplate). The water pressure drop is less than 10kPa at max. Flow rate. Since there is no residual heat or flame Temperatures, The unit does not need copper heat sink piping.
3.INSTALLATION AND CONNECTION 3.5 Swimming Pool Heat Pumps Electrical Wiring NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit, it simply prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect you against short circuits inside the unit.
4.Usage and Operation 4.1.The operation manual of the wire controller μ C CAREDL mute clear 1)About buttons Button Meaning Pressing this button could returning back to the previous interface. mute Function1:continually pressing this button could enter into the set interface. Function2:pressing this button could enter into the next interface.
Page 10
4.Usage and Operation 4.2.The operation of the wire controller 4.2.1 Turn on/off ” or “ ”could start the unit. The screen On the state of power off, pressing(for 5s)“ displays the mode and water inlet temperature; ”or“ ”could turn off the unit. For the On the state of power on,pressing(for 5s)“...
Page 11
4.Usage and Operation 4.2.3 Temperature setting On the state of power on or power off, you could set the heating or cooling temperature. ”and hold for 5s to enter into the parameter setting interface. Press“ ” Press“ ”(Down) to choose the needed setting. Press“ ”to confirm.
5.Maintenance and Inspection 4.2.4 Malfunction When there is something wrong with the unit, the wire controller will display the error code according to the fault reason. For the detailed meanings of the error codes please refer to the Fault Table. For example: Water inlet fault μ...
5.Maintenance and Inspection 5.2 Common observation Look over and clear the failure according to below information. Failure Possible causes for the failure Solutions 1 shut off the power and check power supply; Heat pump 1 Wrong power supply 2 check power cable and make right connection cannot 2 power supply cable loose 3 check for the cause and replace the fuse or...
6.Appendix 6.1 Caution & Warning 1. The unit can only be repaired by qualified installer centre personnel or an authorised dealer.(for Europe market) 2. This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
6.Appendix 6.2 Cable specification 1. Single phase unit Nameplate Creepage protector Signal line maximum Phase line Earth line current No more 2×1.5mm 1.5mm 30mA less than 0.1 sec than 10A 2.5mm 30mA less than 0.1 sec 10~16A 2×2.5mm 30mA less than 0.1 sec 16 ~25A 2×4mm 6 mm...