Omron i4H User Manual page 101

Hide thumbs Also See for i4H:
Table of Contents

Advertisement

Pin Number
19
20
21
22
23
24
25
26
*1.
Only applies when using an XIO Termination Block.
XIO Internal Circuits
Use the following information to understand the XIO internal circuits.
 XIO Input Signals
The twelve inputs are arranged in two banks of six. Each bank is electrically isolated from the other
bank. Each input is optically isolated. The six inputs within each bank share a common source /
sink line.
Input 1.1
Input 1.2
Input 1.3
Input 1.4
Input 1.5
Input 1.6
Common 1
Input 2.1
Input 2.2
Input 2.3
Input 2.4
Input 2.5
Input 2.6
Common 2
 XIO Output Signals
The eight outputs share a common, sourcing driver integrated circuit. The driver is designed to sup-
ply a load with one side connected to ground. Each channel is capable of switching up to 0.7 A of
current. This driver has over-temperature protection, shorted load protection, and is current limiting.
The driver draws power from the 24 VDC Control Power supplied to the robot through a self-reset-
ting polyfuse.
i4H Robots User's Manual (I660)
Designation
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Output 8
3 Installation
*1
Signal Bank
--
3
3-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

I4-650hI4-750hI4-850h