Technical Data; Specifications - RAIS attika Q-Tee II User Manual

Hide thumbs Also See for attika Q-Tee II:
Table of Contents

Advertisement

The technical data given below includes specifications, dimensional drawings and the
information plate.
Danish Technological Institute ref.:
Nominal output (kW)
Min./Max. Output (kW):
Heating area (m
)
2
Fireplace insert width/depth/height
(mm)
Combustion chamber W x D x H (mm)
Min. uptake (pascal)
Weight (kg) min., depending on the
model:
Efficiency (%)
CO emission attributed to 13% O2 (%)
NOx emission attributed to 13% O2
(mg/Nm³)
Particle emission in accordance with
NS3058/3059 (g/kg)
Dust measurement in accordance with
DIN + 13% O2 (mg/Nm³)
Flue gas flow (g/s)
Flue gas temperature (°C)
Recommended amount of wood (kg)
when stoking the fire (Distributed be-
tween 2 logs, each max. 24 cm)
Intermittent operation Stoking should
be done within
The fireplace insert is tested and approved by:
DTI
Danish Technological Institute
Teknologiparken Kongsvang Allé 29
8000 Aarhus C
Denmark
www.dti.dk
Tel.: +45 7220 2000
Fax: +45 7220 1019

TECHNICAL DATA

SPECIFICATIONS

300-ELAB-1882-EN / 300-ELAB-1882-NS
Q-Tee II
6,5
3-8 *
45 - 120
582 / 410 / 598
446 / 277 /
-12
81
0,0791
(989 mg/Nm³)
81
1,868
14
5,2
263
1,8
60 minutter
Q-Tee II C
3-8 *
45 - 120
660 / 479 / 598
167**
446 / 277 /
0,0791
(989 mg/Nm³)
1,868
263
60 minutter
*Not verified by test.
**Max. load
6,5
167**
-12
81
81
14
5,2
1,8
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Attika q-tee ii c

Table of Contents