Pressurizing The Pedestal From An External Pressure Source; Pressurizing The Pedestal Using The Vinten Portable Pump - Vinten Quattro-OBL Operator's Manual

Pedestal
Table of Contents

Advertisement

Pressurizing the pedestal from an external pressure source

WARNING! This pedestal must be pressurized only with clean, dry air or
To pressurize the pedestal from an external pressure source, proceed as follows:
Remove the Schrader valve cap
source.
Push down on the weight tray
the rocker switches to the unlocked position.
Turn on the pressure supply and slowly increase the pedestal pressure to the required pres-
sure. Do not exceed the maximum working pressure, indicated by the leading edge of the
red sector on the gauge (15).
Disconnect the charging line, but do not refit the Schrader valve cap at this stage.

Pressurizing the pedestal using the Vinten portable pump

WARNING! Do not pressurize the pedestal beyond the maximum safe
To pressurize the pedestal using the
Remove the Schrader valve cap (16).
On the pump, fold down both the feet (P.3).
Push in the handle release button
where it will lock.
Pull the hose
(P.4)
(16).
On the pedestal, push down on the weight tray
catches (4), push the rocker switches to the unlocked position.
Position the pump between the legs, standing with both feet on the fold-down feet (P.3).
nitrogen. A pressure reducing valve must be fitted to the pres-
sure line between the gas cylinder and the outlet connection of
the hose. The reducing valve must be screwed into the gas cyl-
inder outlet. The maximum pressure on the outlet side of the
reducing valve must not exceed 16.3 bar (236 psi). Do not pres-
surize the pedestal beyond the maximum safe working pres-
sure indicated by the leading edge of the red sector on the
gauge. The pedestal is fitted with a pressure relief valve as a
safeguard against over-pressurization. Do not attempt to adjust
the pressure relief valve.
(16)
and connect the charging line from the pressure
(2)
against residual pressure. At the safety catches (4), push
working pressure indicated by the leading edge of the red sec-
tor on the gauge. The pedestal is fitted with a pressure relief
valve as a safeguard against over-pressurization. Do not
attempt to adjust the pressure relief valve.
Vinten portable
(P.5)
and move the handle (P.1)to the horizontal position,
out of its stowage (P.2). Connect the hose to the pedestal charging valve
pump, proceed as follows:
(2)
against residual pressure. At the safety