Bitzer OLC-D1-S Technical Information

Opto-electronical oil level monitoring for cs. compressors
Hide thumbs Also See for OLC-D1-S:

Advertisement

Quick Links

技術情報
TECHNISCHE INFORMATION
TECHNICAL INFORMATION
Opto-electronical
Oil Level Monitoring
for CS. Compressors
• OLC-D1-S
1
Application
An adequate oil supply is very important
for the operating life of a compressor.
Lack of lubrication, e. g. due to oil short
age. Even a short interruption of the oil
supply can destroy the roller bearings.
The OLC-D1-S is an opto-electronical
sensor for contactless monitoring of the
oil level by means of infrared light.
Depending on the mounting position and
electrical connection, the same device
can be used for monitoring the minimum
and maximum oil levels.
The monitoring device consists of two
parts: a prism unit and an opto-electronic
unit.
• The prism unit is mounted directly into
the compressor housing.
• The opto-electronic unit is not in direct
contact with the refrigerant circuit. It is
screwed into the prism unit and
integrated into the control circuit of the
plant. An external control module is
not required.
CS. コンプレッサー用
光学式オイルレベルモニター
• OLC-D1-S
1
用途
コンプレッサーを運転する上で、適切な
オイル供給が非常に重要となります。オ
イル切れなどでたとえ短時間でも潤滑油
が不足すると、温度が急上昇してしまう
からです。また短時間でもオイル供給が
中断すると、ローラーベアリングが焼き
付きます。
OLC-D1-S は赤外光利用の非接触光学式
オイルレベルモニターです。
取付け位置と電気的接続を変えること
で、 同じ装置を最小/最大いずれのオイル
レベル監視にも使用できます。
モニター装置を構成する部品は、 プリズム
ユニットと光学式ユニットの 2 つです。
• プリズムユニットはコンプレッサー
ハウジングに直付けします。
• 光学式ユニットは冷媒回路とは直接
接触しません。プリズムユニットにネ
ジ止めされ、プラントの制御回路に統
合されます。外部制御モジュールは必
要ありません。
ST-130-2

Advertisement

loading
Need help?

Need help?

Do you have a question about the OLC-D1-S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bitzer OLC-D1-S

  • Page 1 Lack of lubrication, e. g. due to oil short イル切れなどでたとえ短時間でも潤滑油 age. Even a short interruption of the oil が不足すると、温度が急上昇してしまう supply can destroy the roller bearings. からです。また短時間でもオイル供給が The OLC-D1-S is an opto-electronical 中断すると、ローラーベアリングが焼き sensor for contactless monitoring of the 付きます。 oil level by means of infrared light. OLC-D1-S は赤外光利用の非接触光学式...
  • Page 2 Functions 機能 The OLC-D1-S can monitor either the OLC-D1-S は取付け位置と安全回路への minimum or the maximum oil level, 組込み方次第で、 最小/最大いずれのオイ depending on its mounting position and ルレベルもモニターできます。 最小/最大 incorporation into the safety chain. If the 両方のオイルレベルをモニターする場 minimum and the maximum oil level 合には、2 台の...
  • Page 3 2.2 Monitoring of the maximum level 2.2 最大レベルのモニター The electrical connection and its 装置の電気的接続と制御ロジックへの integration into the control logic depend 組込みは、個々のシステム構成によって on the design of the particular system. 異なります。 Thus, for example, in an installation with たとえば満液式蒸発器の場合、コンプ flooded evaporator, a solenoid valve in レッサー内のオイルレベルに応じてオ...
  • Page 4 イッチボードに取り付ける必要があり a reset button S4 must be mounted in ます。 the switch board. 代わりに、OLC-D1-S をオプションの保 Alternatively, the OLC-D1-S can also be used in combination with the optional 護デバイス SE-C1 と組み合わせて使用 protection device SE-C1 (for schematic することもできます(次ページの配線図 wiring diagram, please refer to next を参照)。...
  • Page 5 (Y/Δ 結線の場合) K4T ..Time relay "oil level switch" 90 s K4 ..補助コンタクター「オイルレベル」 S4 ..Fault reset "oil level" K4T ..タイムリレー 「オイルレベルスイッ チ」90 秒 S4 ..エラーリセット「オイルレベル」 OLC-D1-S opto-electronical oil level OLC-D1-S monitoring 光学式オイルレベルモニター SE-E1 Compressor protection device, SE-E1 コンプレッサー保護デバイス、...
  • Page 6 Mounting 取付け OLC-D1-S をコンプレッサーと一緒に注 If the compressor is ordered with 文した場合、OLCD1- S のプリズムユ OLC-D1-S, the prism unit of the OLCD1- S is already installed. The optoelectronic ニットは最初から組み込まれた状態で unit must only be screwed on and 納入されます。光学式ユニットをネジ止 connected electrically. めし、電気的接続を行えば必要な作業は 終わりです。 Monitoring of the minimum oil level 最小オイルレベルモニター(標準位置)...
  • Page 7 4.1 Prisma-Einheit montieren 4.1 Mounting the prism unit 4.1 プリズムユニットの取付け Prisma-Einheit des OLC-D1-S vor- Mount the OLC-D1-S best before the OLC-D1-S の取付けはできる限りコン compressor is installed. zugsweise montieren, bevor der Ver - プレッサーを据え付ける前に行います。 dichter in die Anlage eingebaut wird. Warnung! Warning! 警告!...
  • Page 8 Sicherstellen, dass der ていることを確認してください。 Kabelanschluss immer nach unten weist! • 光学式ユニットが設置されていない場 • The OLC-D1-S locks out if the • Das OLC-D1-S verriegelt, wenn die 合、 OLC-D1-S はロックアウトします。 opto-electronic unit is not installed. opto-elektronische Einheit nicht montiert ist.
  • Page 9 サー始動直後に目視点検したとき、オイ visible in the lower area of the sight ルレベルがサイトガラスの下半分、また glass, or – if the OLC-D1-S is installed は最大オイルレベルモニター用に for monitoring the maximum oil level – in OLC-D1-S を取り付けている場合は、オ the lower area of the glass cone. For this イルがガラスコーンの下半分の位置に...
  • Page 10 Notes ST-130-2...
  • Page 11 Notes ST-130-2...
  • Page 12 株式会社 ビッツァー・ジャパン 〒560-0082 大阪府豊中市新千里東町 1-4-2 千里ライフサイエンスセンタービル 14F TEL 06-6873-8555 • FAX 06-6873-8556 www.bitzer.jp・info@bitzer.jp Subject to change // Änderungen vorbehalten // // 80311102 // 01.2011 予告なく変更する場合があります。...