INTRODUCTION Thank you for purchasing this CLARKE 50 Litre 110V Industrial Dehumidifier. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.
ELECTRICAL CONNECTIONS WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE POWER SUPPLY. Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. Connecting it to any other power source may cause damage.
Page 4
OVERVIEW Description Handle Control Panel 2 x Wheels Continuous Drainage Pipe Outlet Hole 2 x Feet 5 Litre Internal Water Tank Air Inlet and Filter Air Filter Pull Tab Contents List: 1 x 50L Dehumidifier, 2 x Wheels, 1 x Wheel Axle Rod (Inc: Nuts & Washers), 4 x Axle Fixing Screws, 1 x Drainage Pipe Parts &...
3. This appliance is designed to dehumidify industrial environments and MUST NOT be used for other purposes. 4. If the appliance requires repair, ALWAYS contact your CLARKE dealer. ALWAYS insist on original spare parts. Repairs carried out by unauthorized persons may be dangerous and invalidate the guarantee.
Page 6
WARNING: DO NOT USE OR STORE THE DEHUMIDIFIER NEAR A HEAT SOURCE, AS THE UNIT CONTAINS PRESSURISED FLAMMABLE REFRIGERANT GAS (R290-HYDROCARBON PROPANE) R290 REFRIGERANT GAS (HYDROCARBON PROPANE) H220: Extremely Flammable Gas. H280: Contains Gas Under Pressure, May Explode if Heated. R290 refrigerant gas complies with UK &...
SAFETY SYMBOLS Read the manual Do not cover when and safety in use instructions before Indoor use only Warning: Risk of Fire, Flammable Gas (R290) TECHNICAL SPECIFICATION Power Source AC 110V Input Current @ Rated Load 7.4A @ 30 C RH 80%, 5.5A @ 27 C RH 60% Power 800W @ 30...
Page 8
ASSEMBLY HANDLE 1. Place the machine in the upright position, Lift the handle on the rear of the machine by 180 degrees to the upright position. 2. Secure the handle in position using the screws provided. WHEELS 1. Incline the machine body, as shown, and fix the wheel axle on the bottom of the machine body using the 4 screws.
OPERATION CONTROL PANEL Description Description Timer Subtract Temperature Dehumidification Full Water Tank Humidity Air Speed Power Defrosting Timer Set Button Operation Instructions On/Off (Button 5) Switches the machine On and Off + (Button 8) Adjusts different set values in different states: 1: Increases the humidity value set (RH 10% to 95%) 2: Increases the timing (Hours) set (00 to 24) - (Button 7)
Page 10
WATER TANK & CONTINUOUS DRAINING This machine has a 7 litre internal water tank. When the water tank is full, the machine will automatically shutdown at 5 litres and enter standby mode, on the LED display the ‘Full Water Tank’ will light up and an alarm will sound. TO EMPTY THE TANK 1.
NOTE: The pipe has an internal diameter of 13mm and is 100cm long. NOTE: DO NOT submerge the end of the pipe in water, as this may cause water to be drawn back up into the machine. TIMING AND ON/OFF FUNCTION Setting the timer for both powering on and off will initiate the cycle timer mode.
• When started, the compressor will start 3 seconds later and when it is shut down, the fan will run for 3 seconds. • If a fault of the humidity sensor occurs, the machine will turn to the continuous dehumidifying mode. •...
MAINTENANCE WARNING: ALWAYS UNPLUG THE DEHUMIDIFIER BEFORE PERFORMING ANY CLEANING OR MAINTENANCE OPERATIONS. CLEANING THE CABINET • Use a soft damp cloth to clean the exterior. • Never use harsh chemicals or abrasive cleaning agents as these may damage the casing finish. •...
TROUBLESHOOTING Cause Solution No operation Power outage Check if the power supply is in (Shown as no working order. power) Confirm the plug is correctly inserted in the power socket. Fuse in plug or fuse board Replace the relevant fuse. blown No operation Environmental humidity...
Fault with coil sensor See Defrosting Mode. E2/E3 Fault with humidity and/or Replace temperature temperature sensor and humidity sensor. Refrigerant leakage Contact CLARKE service department if EE signal remains. ELECTRICAL DIAGRAM Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
COMPONENT PARTS LIST Description Description Handle Power Strip 4 x Bolt & Nut, M6 x 35 Fan Motor Capacitor Handle Bracket Control Box Side Plate Back Cover Water Tank Bracket Discharge Pipe Water Tank Support Plate Suction Pipe Main Body Base Plate Control Panel Label Foot Bracket Control Panel...
Page 18
DECLARATION OF CONFORMITY - UKCA Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
Page 19
ASSOCIATED 110V PRODUCTS EURO5 Generator - 12” Ventilator/Air Mover 2.8kW Electric Fan PG3800ADV - CON305 Heater- Devil 3003 •Max Output:3000W •Fan Dia.: 12” (300mm) •Adjustable Thermostat •5.6HP Petrol Engine •Air Flow: 3900m3/h •Weight: 6.15kg •Dims(LWH):600mm x •Dims(LWH):375mm x •Dims(LWH):400mm x 480mm x 445mm 386mm x 430mm 260mm x 390mm...