  • Page 1 50L INDUSTRIAL DEHUMIDIFIER MODEL NO: IDH50L PART NO: 6470611 OPERATION & MAINTENANCE INSTRUCTIONS DL0422 Iss 1...
  • Page 2: Environmental Recycling Policy

    INTRODUCTION Thank you for purchasing this CLARKE 50 Litre Industrial Dehumidifier. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.
  • Page 3: Electrical Connections

    ELECTRICAL CONNECTIONS WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY. Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz.
  • Page 4 OVERVIEW Description Handle Control Panel 2 x Wheels Continuous Drainage Pipe Outlet Hole 2 x Feet 5 Litre Internal Water Tank Air Inlet and Filter Air Filter Pull Tab Contents List: 1 x 50L Dehumidifier, 2 x Wheels, 1 x Wheel Axle Rod (Inc: Nuts & Washers), 4 x Axle Fixing Screws, 1 x Drainage Pipe Parts &...
  • Page 5: Safety Warnings

    3. This appliance is designed to dehumidify industrial environments and MUST NOT be used for other purposes. 4. If the appliance requires repair, ALWAYS contact your CLARKE dealer. ALWAYS insist on original spare parts. Repairs carried out by unauthorized persons may be dangerous and invalidate the guarantee.
  • Page 6 WARNING: DO NOT USE OR STORE THE DEHUMIDIFIER NEAR A HEAT SOURCE, AS THE UNIT CONTAINS PRESSURISED FLAMMABLE REFRIGERANT GAS (R290-HYDROCARBON PROPANE) R290 REFRIGERANT GAS (HYDROCARBON PROPANE) H220: Extremely Flammable Gas. H280: Contains Gas Under Pressure, May Explode if Heated. R290 refrigerant gas complies with UK &...
  • Page 7: Safety Symbols

    SAFETY SYMBOLS Read the manual Do not cover when and safety in use instructions before Indoor use only Warning: Risk of Fire, Flammable Gas (R290) TECHNICAL SPECIFICATION Power Source AC 230V 50Hz Input Current @ Rated Load 4.0A @ 30 C RH 80%, 3.4A @ 27 C RH 60% Power...
  • Page 8 ASSEMBLY HANDLE 1. Place the machine in the upright position, Lift the handle on the rear of the machine by 180 degrees to the upright position. 2. Secure the handle in position using the fixing screws provided. WHEELS 1. Incline the machine body, as shown, and fix the wheel axle on the bottom of the machine body using the 4 screws.
  • Page 9: Operation

    OPERATION CONTROL PANEL Description Description Timer Subtract Temperature Dehumidification Full Water Tank Humidity Air Speed Power Defrosting Timer Set Button Operation Instructions On/Off (Button 5) Switches the machine On and Off + (Button 8) Adjusts different set values in different states: 1: Increases the humidity value set (RH 10% to 95%) 2: Increases the timing (Hours) set (00 to 24) - (Button 7)
  • Page 10 WATER TANK & CONTINUOUS DRAINING This machine has a 7 litre internal water tank. When the water tank is full, the machine will automatically shutdown at 5 litres and enter standby mode, on the LED display the ‘Full Water Tank’ will light up and an alarm will sound. TO EMPTY THE TANK 1.
  • Page 11: Humidity Control

    NOTE: The pipe has an internal diameter of 13mm and is 100cm long. NOTE: DO NOT submerge the end of the pipe in water, as this may cause water to be drawn back up into the machine. TIMING AND ON/OFF FUNCTION Setting the timer for both powering on and off will initiate the cycle timer mode.
  • Page 12: Protection Function

    • When started, the compressor will start 3 seconds later and when it is shut down, the fan will run for 3 seconds. • If a fault of the humidity sensor occurs, the machine will turn to the continuous dehumidifying mode. •...
  • Page 13: Maintenance

    MAINTENANCE WARNING: ALWAYS UNPLUG THE DEHUMIDIFIER BEFORE PERFORMING ANY CLEANING OR MAINTENANCE OPERATIONS. CLEANING THE CABINET • Use a soft damp cloth to clean the exterior. • Never use harsh chemicals or abrasive cleaning agents as these may damage the casing finish. •...
  • Page 14: Troubleshooting

    TROUBLESHOOTING Cause Solution No operation Power outage Check if the power supply is in (Shown as no working order. power) Confirm the plug is correctly inserted in the power socket. Fuse in plug or fuse board Replace the relevant fuse. blown No operation Environmental humidity...
  • Page 15: Display Codes

    Fault with coil sensor See Defrosting Mode. E2/E3 Fault with humidity and/or Replace temperature temperature sensor and humidity sensor. Refrigerant leakage Contact CLARKE service department if EE signal remains. ELECTRICAL DIAGRAM Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
  • Page 16: Component Parts Diagram

    COMPONENT PARTS DIAGRAM Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
  • Page 17: Component Parts List

    COMPONENT PARTS LIST Description Description Handle Water Tank Bracket 4 x Bolt & Nut, M6 x 35 Control Box Handle Bracket Power Strip Back Cover Fan Motor Capacitor Discharge Pipe Control Box Side Plate Suction Pipe Water Tank Bracket Control Panel Label Water Tank Support Plate Control Panel Main Body Base Plate...
  • Page 18 DECLARATION OF CONFORMITY - UKCA Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
  • Page 19: Declaration Of Conformity (Ce)

    DECLARATION OF CONFORMITY - CE Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...