Securing The Burner To The Boiler - Riello RX 2500 S/E Installation, Use And Maintenance Instructions

Premix gas burners
Table of Contents

Advertisement

4.7

Securing the burner to the boiler

Prepare a suitable lifting system using the
rings 3)(Fig. 12), after removing the fixing screws 7)
of the casing 8).
 Prepare a suitable lifting system using the rings 3)(Fig. 12) of
the head assembly.
 Check
the
correct
gasket 6)(Fig. 13); the black side must be faced the burner
flange and the white one to the boiler side.
 Insert the head assembly on the previously prepared boiler
hole (Fig. 12) and fix with the M18 screws.
 Remove the rings 3) from the head assembly 1).
 Lift the burner by means of the rings 3)(Fig. 12) after having
removed the cover 8) fixing screws 7)(Fig. 12).
 Fix the burner onto the head assembly with the supplied
screws 5)(Fig. 12).
 After the start-up, check there is no leakage of flue gases into
the external environment.
The seal between burner and boiler must be air-
tight.
WARNING
positioning
of
the
insulating
Installation
3
19
GB
20122719
1
3
5
3
3
6
A
B
Fig. 12
20129398
Fig. 13
20140257