1 Application and Function
®
This AMTRON
S3 / AMTRON
closed heating, cooling or heating / cooling system.
2 Contents of the Package
-
Heat meter or heat/cooling meter, consisting of a calculator, a flow sensor and two temperature sensors,
all permanently connected to each other
-
Installation kit (depending on type)
-
Installation and Operating Instructions
-
Operating Instructions „Communication Interfaces S3(C)" (with meters with an optional interface)
-
Declaration of Conformity
3 General Information
-
Valid standards for the application of heat meters: EN 1434, parts 1 – 6; the Measuring Instruments
Directive 2014/32/EU, Annexes I and MI-004; and the relevant national verification regulations.
-
For the selection, installation, commissioning, monitoring and maintenance of the instrument observe the
standard EN 1434 part 6, as well as the verification regulations PTB TR K8 + K9 for Germany (and any
relevant national verification regulations in other countries).
-
For combined heat/cooling meters the cooling register has no verification. National regulations for the
consumption measurement of cooling must be observed.
-
The technical regulations for electrical installations must be observed.
-
This product fulfils the requirements of the European Council Directive on Electromagnetic Compatibility
(EMC Directive) 2014/30/EU.
-
The identification plate of the instrument and the seals must not be removed or damaged – otherwise the
guarantee and the approved application of the instrument are no longer valid!
-
To achieve measurement stability of the meter it is necessary that the water quality meet the requirements
of the AGFW-recommendation FW-510 and the document VDI (Association of German Engineers) VDI 2035.
-
The heat meter left the factory in conformance with all applicable safety regulations. All maintenance and
repair work is to be carried out only by qualified and authorized technical personnel.
-
Instruments with activated radio function are not allowed on air freight.
-
The correct installation point in the system must be chosen: inlet or outlet flow (see item 3.1 'Pictograms
installation point').
-
The temperature sensor cables and the cable between the calculator and flow sensor must not be kinked,
rolled up, lengthened or shortened.
-
To clean the heat meter (only if necessary) use a slightly moist cloth.
-
To protect against damage and dirt the heat meter should only be removed from the packaging directly
before installation.
-
If more than one heat meter is installed in one unit, care must be taken to ensure that all the meters have
the same installation conditions.
-
All specifications and instructions listed on the data sheet and in the Application Notes must be adhered to.
Further information can be obtained at www.engelmann.de.
-
The heat meter has a lithium-metal-battery. Do not open the batteries, do not bring the batteries into
contact with water or expose them to temperatures above 80 °C. Do not charge them or short-circuit them.