Self-Check; Self-Check Procedure; If An Error Is Detected In The Self-Check - Renesas Emulation Pod for M16C/80 Group MCUs M30803T-RPD-E User Manual

Emulation pod for m16c/80 group mcus
Table of Contents

Advertisement

4.4 Self-check

(1) Self-check Procedure

To run the emulator self-check, do so as explained here below. While the self-check is in progress,
LEDs will change as shown in Figure 4.5.
Figure 4.4 Switch settings when running the self-check

(2) If an Error is Detected in the Self-check

If the self-check does not result normally (ERROR 1 or ERROR 2 in Figure 4.5), check the following.
Note on Self-check:
(1) Set the switches in the emulation pod same as the factory setting (see Figure 4.4).
(2) When the target system is connected, disconnect the target system.
(3) Within 2 seconds of activating power to the emulator, press the RESET button on the emulator
front panel to switch the emulator to maintenance mode.
(4) Check the "SAFE" LED starts flashing and then press the RESET button again.
(5) The self-check will start. If the normal result is displayed in about 1 minute, the self-check has
terminated normally.
• Check the connection of the emulation pod and the PC4701.
• Redownload the proper firmware.
• Check if the switches in this product is set same as the factory-setting ("Figure 3.2 Positions of
switches and their factory-settings", page 25).
• If the self-check does not result normally (excluding target system errors), the
emulation pod may be damaged. Contact your local distributor.
IMPORTANT
( 53 / 74 )

Advertisement

Table of Contents
loading

Table of Contents