The piano should s ll be disconnected from AC power.
Insert straps in the bracket.
A ach the magne c bracket to the piano and the processor to the magnet.
A ach the two antennas to the end of the PNO3WB processor.
The center RFC connector is NOT used.
 
ETHERNET
Do NOT connect an Ethernet
  USB HOST‐The USB HOST ports are the same so, the cables can be re‐inserted in either socket. 
USB CLIENT
MIDI IN‐This port may be connected to a MIDI Record strip.
AUDIO 1‐4 [Audio #3 goes the piano speaker]
The silver "contact" side of the ribbon cable faces down, away from the label.
DO NOT insert the SD card.
The QRS Music Library is now stored INSIDE the PNO
DRIVER PORT B and PWM Control
Connect the driver board cable to the appropriate socket on the PNO3WB processor.
There are three possible driver board cables:
1 Driver Port B, black socket: 8‐wire harness to Smart Driver Boards
2 Driver Port B, white socket: 20‐pin ribbon to Rev 4 boards OR old style Magne c adapter.
Orient the silver contacts of the ribbon cable to the contacts of the connector!
3 PWM Control, 20‐Pin ribbon to Rev 7 boards OR 37‐Pin new style Magne c adapter.
PMII
Connect the Power supply and PLx cables.
Verify that the QRS power supply switch is OFF before connec ng this cable.
NEVER connect the POWER SUPPLY and DC 9VDC cables to the same processor.
Record System, if installed.
PNOscan 10 [On systems with the QRS PNOscan record installed.]
Came from the PMII processor's KEYSCAN PRIMARY connector.
The silver "contact" side of ribbon faces away from PNOscan 10 label.
MIDI IN, from a KS1 Record Interface...as an example.
4
QRS PMII to PNO3WB Upgrade Instruc ons
Mount and Connect the PNO3WB Processor
Connect the cables to the PNO3WB processor
cable. The PNO3WB has built‐in WiFi.
Insert straps through slots
3
WB processor.
QRS System
3
PNO
WB

Advertisement