15 Maintenance and Repairs

15.1
Maintenance Intervals
The maintenance intervals are dependent on the
environmental and operating conditions. STIHL
recommends the following maintenance inter‐
vals:
Every 12 months
► Have the blower checked by a STIHL servic‐
ing dealer.

16 Troubleshooting

16.1
Troubleshooting the Blower and Battery
Fault
LEDs on the
battery
The blower does
1 LED flashing
not start when
green.
switched on.
1 LED emits
red light.
3 LEDs flash
red.
3 LEDs light up
red.
4 LEDs flash‐
ing red.
The blower turns
3 LEDs light up
off while in oper‐
red.
ation.
14
15.2
The blower cannot be serviced or repaired by the
user.
► If your blower has a malfunction or is dam‐
aged or requires servicing: Contact your
STIHL servicing dealer.
Cause
State of charge of the
battery is too low.
The battery is too
warm or too cold.
There is a fault in the
blower.
The blower is too
warm.
There is a fault in the
battery.
No electrical contact
between the blower
and the battery.
The blower or the bat‐
tery is damp.
Trigger is pressed
before operating the
release slide.
The blower is too
warm.
There is an electrical
fault.
15 Maintenance and Repairs
Servicing and Repairing the
Blower
Remedy
► Charge battery as described in the User
Manual for chargers STIHL AL 101, 301,
301-4, 500.
► Pull the connecting cable plug out of the
socket.
► Allow the battery to cool down or warm
up.
► Pull connecting cable plug out of the
socket and plug it in again.
► Turn on the blower.
► If 3 LEDs continue to flash red: Do not
use the blower and contact your STIHL
dealer for assistance.
► Pull the connecting cable plug out of the
socket.
► Allow the blower to cool down.
► Pull connecting cable plug out of the
socket and plug it in again.
► Turn on the blower.
► If 4 LEDs continue to flash red: Do not
use the battery; contact a STIHL author‐
ized dealer.
► Pull connecting cable plug out of the
socket and plug it in again.
► If blower still does not start when
switched on: Clean contacts of connect‐
ing cable as described in the User Man‐
ual for the STIHL AR battery or the "AP
belt bag with connecting cable".
► Allow blower or battery to dry.
► Turn on the blower as described in this
user manual.
► Pull the connecting cable plug out of the
socket.
► Allow the blower to cool down.
► Pull connecting cable plug out of the
socket and plug it in again.