Edid Modes; Cec Control; Ip To Cec; Edid Modes And Smart Cec Control - Gefen GTB-UHD600-18S-RT User Manual

Table of Contents

Advertisement

EDID Modes

• Internal Mode - 4K 600Mhz / 2 Channel Audio
• Internal Mode - 4K 600Mhz / Multi-Channel Audio
• Internal Mode - 720P / 2 Channel Audio
• Internal Mode - 720P / Multi-Channel Audio
• Internal Mode - 1080P / 2 Channel Audio
• Internal Mode - 1080P / Multi-channel Audio
• External Mode - EDID copied upon boot up from connected sink on HDMI output 1. When
no output is detected, it will search in numerical order for a valid output.
*This is configured via IP (Telnet/UDP) or Virtual Serial Port

CEC Control

This product will feature CEC control capabilities that will enable specific functions to be
implemented:
CEC Always On – When this feature is enabled (by default), the unit will issue a CEC 'Power
h
On' command to all outputs simultaneously at specific, user defined (default value is 10
seconds) intervals that will ensure that a display is always on.
CEC 'Power On' – Sends a command via TCP/IP to turn on one or all sink devices on using
h
CEC.
h
CEC Auto Off – When this feature is enabled (disabled by default), a valid CEC 'Power Off'
from a connected source device on the active HDMI input will trigger a CEC 'Power Off'
command that is output from all HDMI outputs simultaneously.
For example: This feature can be used to cascade a CEC 'Power Off' command via the
HDMI outputs to be relayed to downstream HDMI products (e.g. additional splitter products
with the same feature that can turn off displays).
CEC Auto Input Selection – When this feature is enabled (by default) the unit will issue
h
a CEC 'HDMI Input XX' command to all outputs simultaneously at specific, user defined
(default value is 10 seconds) intervals that will ensure that 'HDMI Input XX' is the preferred
and used input should a user change the sink's input value.
For example: XX is defined as the input that is currently connected from the sink device to
the unit.
h
CEC is not 'Passthrough' on this product.

IP to CEC

This feature allows a CEC command to be sent to any source or any display. Refer the API
Commands List,
page
Detailed information for #SEND_INPUT_CEC can be found on
#SEND_OUTPUT_CEC command can be found on

EDID Modes and Smart CEC Control

31, for #SEND_INPUT_CEC and #SEND_OUTPUT_CEC commands.
page
page
35.