NetSure™ 211 SERIES
-48 VDC Battery Cabinet
Installation and User Manual (Section 6023), Revision L
Specification Number: 541434
Model Number: 211
BC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NetSure 211 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vertiv NetSure 211 Series

  • Page 1 NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation and User Manual (Section 6023), Revision L Specification Number: 541434 Model Number: 211...
  • Page 2 If you encounter any installation or operational issues with your product, check the pertinent section of this manual to see if the issue can be resolved by following outlined procedures. Visit https://www.vertiv.com/en-us/support/ for additional assistance. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 3: Table Of Contents

    Installing Eaglepicher HE-12V7.7FR Batteries................. 19 Installing Enersys NP18-12FR Batteries ..................20 Securing the Batteries Using the Strap ..................25 Typical Internal Wiring Layout ....................... 27 Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 4: Admonishments Used In This Document

    SAFETY! Informs the reader of general safety information, reminders, precautions, or policies not related to a particular source of hazard or to fire safety. (ISO, ANSI, OSHA) Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 5: Important Safety Instructions

    Even a momentary short circuit can cause sparking, explosion, and injury. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 6: Battery

    • Do not open or mutilate batteries. • ALWAYS FOLLOW THE BATTERY MANUFACTURER’S RECOMMENDATIONS AND SAFETY INSTRUCTIONS. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 7: Personal Protective Equipment (Ppe)

    Permits as required by the local authority, per NFPA 70E “Standard for Electrical Safety in the Workplace”. Hazardous Voltage DANGER! HAZARD OF ELECTRICAL SHOCK. More than one disconnect may be required to de-energize the system before servicing. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 8 This page is intentionally blank. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 9: Introduction

    SBS15 139091 12.50 Fiamm 12SLA12 139092 12.35 EaglePicher HE-12V12.7FR 139093 11.6 * 9.70 EaglePicher HE-12V7.7FR 139094 6.40 Enersys NP18-12FR 139774 16 * 13.60 Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 10: Specifications

    Mounting the Battery Cabinet The battery cabinet is designed to mount on a wall or a standard 19” or 23” wide relay rack. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 11: Relay Rack Method

    Ensure that connector, wires and bushing located at the back are moved to the side, as shown in Figure 4, before mounting the cabinet. Install battery retention strap through openings in rear of cabinet. Orient the buckle per Figure 28. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 12 Ensure the technique and hardware used in securing the cabinet can support the total weight of the cabinet and the batteries. Refer to “Batteries” on page 9 for a battery weight reference table. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 13: Connecting Battery Cabinet(S) To The Associated Power System

    Connect the second battery cabinet’s battery cable terminated in an Anderson connector to the fixed mating Anderson connector located on the first battery cabinet. Repeat the above step if there are additional battery cabinets. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 14 P/N 565513. P/N 545696 is always used. P/N 565513 is used only with power systems containing a 1M831ANA Mini Controller (may be discarded if battery cabinet is used with other systems). Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 15: Installing Enersys Sbs15 Batteries

    Supplied Supplied - Wire quick quick connect connect Supplied cables Attach the cabinet wires to + and - terminals. Refer to Figure 10. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 16: Installing Fiamm 12Sla12 Batteries

    Connect all four Fiamm batteries using supplied wires (Part Number 541420) crimped with 12-10 AWG ring lug on each end, as shown in Figure 12. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 17: Installing Eaglepicher He-12V12.7Fr Batteries

    Procedure Place the batteries inside the cabinet. Refer to Figure 14. Break each spacer at its score line and insert between the batteries. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 18 Connecting EaglePicher 12V12.7FR Batteries - Wire Supplied cables + Wire Attach the cabinet wires to + and - terminals. Refer to Figure 16. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 19: Installing Eaglepicher He-12V7.7Fr Batteries

    Connect all four EaglePicher batteries using wires (Part Number 541424) crimped with 12-10 AWG Faston receptacle on each end, as shown in Figure 18. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 20: Installing Enersys Np18-12Fr Batteries

    A parts kit (P/N 545427), which is purchased in addition to the cabinet includes the following pieces: • (1) Long rear spacer • (8) Fast-on terminals • (3) Fast-on lugged cables • Mounting hardware Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 21 Attach fast-on lugs using the provided hardware to the first battery that will be located on the left hand side of the cabinet. See Figure 22. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 22 Set first battery in cabinet and attach the long lead (fast-on connector side marked positive) from the cabinet to the fast-on terminal on the positive terminal of the battery. See Figure 24. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 23 Set second battery in cabinet and attach the other end of the fast-on lugged cable to the negative terminal on the first battery (fast-on terminal). See Figure 26. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 24 Refer to “Securing the Batteries Using the Strap” on page 25 for instructions on securing the batteries using the buckle strap that is bundled along with the cabinet. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 25: Securing The Batteries Using The Strap

    This will ensure the proper tension is applied to the strap. To release buckle, pull outward on free strap end. Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 26 Figure 30: Securing the Batteries in the Cabinet Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 27: Typical Internal Wiring Layout

    OTHER BATTERY CABINET BATT BATT BATT BATT 49.9 ohm TO DIGITAL IN PUT ON TO OTHER IB0 OR IB2 PW BOARD BATTERY CABINET Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023) | Rev. L...
  • Page 28 Vertiv.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA © 2021 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp.

This manual is also suitable for:

Netsure 211bc

Table of Contents