How To
Install and Set Up the 5900 &
7900 Printer
One of two types of cable is supplied. The cables have the same specification but the colours
of the wires are different. The wire colours in the cable are as follows.
WIRE COLOUR
Green-Yellow
Blue
Brown
WARNING: THIS PRINTER MUST BE EARTHED/GROUNDED.
WARNING: THE PRINTER MUST BE ELECTRICALLY WIRED ONLY BY A QUALIFIED AND
COMPETENT ELECTRICIAN. LINX CANNOT ACCEPT RESPONSIBILITY FOR ANY INJURY TO
PERSONNEL OR DAMAGE TO MACHINERY CAUSED BY INCORRECT OR FAULTY WIRING.

1.7 Fit the printhead to the production line

You can set the printhead at any angle. Use a Linx printhead bracket to hold the printhead
correctly and prevent vibration—a number of bracket types are available.
The distance between the end of the printhead and the product is the 'throw distance'. To
make sure that the print quality is good, set the throw distance to the recommended
distance shown in the table below.
Printhead
Midi
Ultima
Midi plus
Ultima plus
Mini
Micro (7900 only)
25
Green
White
Black
Figure 2. Wire colours
Recommended distance
6 mm for a 25 Linear Speed message type,
12 mm for all other message types
12 mm
12 mm
12 mm
The first digit in the name of the message type is the throw distance in
millimetres. For example '4T...' indicates 4 mm. For the 5900, only 4 mm
and 8 mm throw distances are available. The 7900 printer also has a
12 mm throw distance available.
4 mm
Figure 3. Recommended throw distances
Page 4 of 25
CONNECTION
Earth/Ground
Neutral
Live
FA69372–2 English
Jun 2013

Advertisement

Table of Contents
loading

This manual is also suitable for:

7900