Technical Data; Disposal; Notes On Troubleshooting - Nice elero Revio-868 SW Operating Instructions Manual

Hide thumbs Also See for elero Revio-868 SW:
Table of Contents

Advertisement

Technical Data

Programming further transmitters
→ see transmitter instructions
With multi-channel transmitters, it is not possible to use the central
channel.
Programme positions
→ see transmitter instructions
Approach positions
→ see transmitter instructions
Deleting positions/deleting transmitters
→ see transmitter instructions
Technical Data
Nominal voltage
230 to 240 V AC / 50 to 60 Hz
Switching current
3 A
Standby
0.6 W
Protection type
IP20
Permitted
0 to 50 °C
ambient temperature
Radio frequency
868 MHz frequency band
Type of mounting
Concealed socket Ø 58 mm, depth 60
mm. Surface-mounted in corresponding
housing
Dimensions
L 50 x W 48 x H 27 mm
Maximum number of
16 transmitters
transmitters
14 | EN
Ⓒ elero GmbH
Troubleshooting / Declaration of Conformity

Disposal

Dispose of the device according to the current electrical waste
disposal regulations of the country concerned (e.g. suitable collec-
tion points).

Notes on Troubleshooting

Fault
Cause
Drive does not run
False connection
Drive operates in
• Directions are incor-
the wrong direction
rectly programmed.
• Connections
are swapped
No radio reception
• Transmitter is not
programmed
• No mains voltage
Bad radio recep-
Aerial or receiver in
tion
unfavourable position.
Declaration of conformity
elero GmbH hereby declares that the Revio-868 SW complies
with the basic prerequisites and the other relevant provisions of
the EC directives. The complete declaration of conformity can be
found in the download area of our website.
Ⓒ elero GmbH
Remedy
Check connection.
• Delete transmitter
and program cor-
rectly.
▲ and
• Swap connections
▲ and ▼
• Programming the
transmitter
• Switch on power
supply.
Change position of
receiver or aerial.
EN | 15

Advertisement