5. Data Report

The device will immediately send a version packet report along with an uplink packet including temperature, humidity and
battery voltage.
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime: Max Interval = 15 min = 900s
MinTime: Min Interval = 15 min = 900s
BatteryChange: 0x01 (0.1V)
TemperatureChange:0x0064 (1°C)
HumidityChange:0x0064 (1%)
Note:
The device report interval will be programmed based on the default firmware which may vary.
The interval between two reports must be the minimum time.
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Any number between
1~65535

5.1 Example of ReportDataCmd

FPort:0x06
Bytes
1
Version
Version– 1 byte –0x01——the Version of NetvoxLoRaWAN Application Command Version
DeviceType– 1 byte – Device Type of Device
The devicetype is listed in Netvox LoRaWAN Application Devicetype doc
ReportType – 1 byte –the presentation of the NetvoxPayLoadData,according the devicetype
NetvoxPayLoadData– Fixed bytes (Fixed =8bytes)
to resolve uplink data.
Max Interval
(Unit:second)
Any number between
1~65535
1
1
DeviceType
ReportType
Reportable Change
Can not be 0.
5
Current Change≥
Reportable Change
Report
per Min Interval
Var(Fix=8 Bytes)
NetvoxPayLoadData
Current Change<
Reportable Change
Report
per Max Interval