  • Page 1 INSTALLATION MANUAL GOODWE PVBM UP TO A SUSTAINABLE FUTURE S U N S H I N E T I L E & V E N U S T I L E GOODWE AUSTRALIA PTY. LTD. sales@goodwe.com.cn service.au@goodwe.com.cn...
  • Page 2 Sunshine Tile User Installation Guide Manual 2021-9-30...
  • Page 3: Table Of Contents

    Content 1. Description of the main construction of the Sunshine Tile ........... 2 2. List of Installation Accessories ....................3 3. Installation Tools ........................3 4. Installation Tools and Spare Parts of Electrical Part ............... 4 5. Pre-installation Inspection ..................... 4 6.
  • Page 4: Description Of The Main Construction Of The Sunshine Tile

    Sunshine Tile front The back of the Sunshine Tile Installation height:Altitude <2000m Fire rating: Sunshine Tile fire rating is CLASS A according to the corresponding certification standard (IEC61730-2-MST23) Protection Class: Class II Mechanical load: maximum static load of 5400Pa on the front; maximum static load of...
  • Page 5: List Of Installation Accessories

    ≥100mm and stone Tool saw blade) name Note: This list only indicates the main tools and implements required for the installation of Sunshine Tile structure system, excluding the tools used for the installation of roofing bracket part and electrical part.
  • Page 6: Installation Tools And Spare Parts Of Electrical Part

     It is strictly forbidden to put Sunshine Tile in direct contact with any rigid material when installing the tile, otherwise it will cause breakage of Sunshine Tile.
  • Page 7: The Installation Of Sunshine Tile

    15 pieces, otherwise the components may be damaged and fall off. ③、When the Sunshine Tile is temporarily leaning and placed, it is forbidden to squeeze the Sunshine Tile connecting cable between the two Sunshine Tile frames to avoid breaking the cable due to pressure.
  • Page 8 and anti-moth treatment. The connection between counter batten and nail- supporting layer and the connection between tile batten and counter batten should be fixed firmly. 5、 Counter batten installation. ① The size of the counter batten should not be less than 40*30(H) mm (optional specification).
  • Page 9 Tile batten Installation Tile batten installation profile 7、 Sunshine Tile installation Sequence: Install from right to left in the same row, and install row by row from bottom to top. ① Install the matched tiles at the cornice first and the order of installation is from...
  • Page 10 Sun Tile. Each piece of Sunshine Tile needs 2 installation hooks and 4 mounting screws. The position relationship between the...
  • Page 11 Hook centre 367mm from the edge of the left edge of the Sunshine Tile Hook centre 367mm from the edge of the left edge of the Sunshine tile. ③After confirming the location of the installation hooks, lay the bottom row of installation hooks first;...
  • Page 12 Layout details of the installation hooks ④After completing the installation of the installation hooks for the entire row of Sunshine Tiles, install the matched tiles on the far right side of this row; (as shown below) Installation of the right side matched tile...
  • Page 13 ⑥The left and right lap of Sunshine Tiles are installed as below: Sunshine Tile lap with right side matched tile (left profile) The lap of the left and right frame of Sunshine Tile (middle profile) Sunshine Tile lap with left side matched tile (right profile) ⑦The edge tiles, which are left or right lapped directly to the Sunshine Tiles must...
  • Page 14 previous row of Sunshine Tiles already installed. ⑨After each row of Sunshine Tiles is installed, check its lap condition with the previous row of Sunshine Tiles to avoid blocking the solar cells of the previous row of Sunshine Tiles. ⑩The lap distance between the upper and lower rows of tiles is 51mm±5mm (as shown below).
  • Page 15 8、 Construction of the ventilated ridge (installation of brackets, waterproofing membrane and ridge tiles) ① Fix the brackets using the snapped structural lines of the main and hip ridges as a reference line. The method is as follows: adjust the brackets by the measured height of the brackets during pre-laying, fix one section to the wooden brackets with screws and the other side to the counter batten with steel nails/shoot nails, and then fix 50 x 40mm brackets (antiseptic treatment required) to the brackets,...
  • Page 16 ② Install the top row of edge tiles ③ Lay the waterproofing membranes ④ Install the ridge tiles: pre lay the ridge tiles and fix the ridge tile with the ridge tile screw after confirming that there are no problems. (main and hip ridges are installed in the same method)
  • Page 17 ① The grounding wire can be connected to the grounding hole on the left frame of the Sunshine Tile in the box uniformly before installation: install the serrated washer, grounding wire and self-tapping screw (diameter ≥ 4.8 mm) in turn and...
  • Page 18 Sunshine Tile frame are connected into a conductive path leading to the bus, which is connected to the grounding flat iron buried in the earth (Figure...
  • Page 19: Electrical Installation

    7. Electrical installation 7.1 Electrical performance The nominal values of the module electrical performance parameters such as Isc, Voc and Pmax have an error of ± 3% under standard test conditions (Irradiance 1000 W/m2, cell temperature 25°C, atmospheric mass AM1.5). When the modules are connected in a series, the final voltage is the sum of the series modules;...
  • Page 20 conditions ( Maximum system voltage of the module is DC1000V/DC1500V - the actual system voltage will depend on the module type and inverter selected ) and other values required for DC electrical components. The open circuit voltage correction factor can be calculated according to the following formula:CVoc=1-βVoc×(25-T).
  • Page 21 2、Preparation of main tools ① Multimeter: used to measure the open circuit voltage of Sunshine Tile; ② Electric welding machine: used for lightning protection and grounding of bracket; ③ Angle measuring instrument, level instrument, etc: measure the installation angle...
  • Page 22 When it is to be installed on the Sunshine Tile at the other end of the jumper cable, complete the installation of the other end. (as shown in figure 7-2-...
  • Page 23: Electrical Construction Technology

    Sunshine Tile installation layout drawing in each project. 7.7 Installation requirements of Junction Kit ① Please connect the Junction kit with the Sunshine Tile array according to the electrical schematic diagram; ② The butt plug shall be inserted firmly;...
  • Page 24 ① Impact drill: used for drilling holes in the installation position of PVC pipe and pipe clamps; ② MC4 DC cable special crimping pliers: used for on-site production of DC MC4 plugs; ③ Multimeter and megohmmeter: used for cable conduction and insulation testing; ④...
  • Page 25 ⑦ Try to avoid high-temperature heating objects as far as possible; ⑧ Cable pipes need to be fixed; ⑨ Both ends of the AC and DC cables connected to the inverter and distribution box must be marked with the circuit cable number. Method of MC4 cable connector: ①...
  • Page 26 8.2.4 Sunshine Tile array Before starting the inverter, check the on-site Sunshine Tile array to check whether the open circuit voltage of each Sunshine Tile meets the requirements. ① Accurately record all values measured on site;...
  • Page 27 2. Sunshine Tile DC side wiring ① Do not open the junction box on the back of the Sunshine Tile; ② Do not directly touch the positive and negative poles of the Sunshine Tile plate with your hands; ③ Do not directly unplug the positive and negative terminals of the string when power is supplied;...
  • Page 28: Sunshine Tile Disassembly And Repair

    9.1 Sunshine Tile disassembly 1. The first step is to push the Sunshine Tile which is needed to be repaired upward and flat, so that the lower end of the Sunshine Tile comes out of the hook. (As shown below) 2.
  • Page 29: Matters Need Attention

     Connect the cables of the replacement tile with other tile firmly; test whether the circuit is connected intact  Push the replacement Sunshine Tile upward and flat.  Flatten the Sunshine Tile and pan down, and the replacement Sunshine Tile can fall into the slot of the mounting hook.  Finish the work.
  • Page 30: Appendix

    high-current equipment such as welding machines and motors. 11. Appendix Product specifications 1. Module Type of BMT-S1/032A 组件类型 Module Type BMT-S1/032A (85W, 90W, 92W, 95W) 电气性能 Electrical Properties 测试条件 Testing Condition 1000W/m²,25℃,AM 1.5G spectrum 功率等级 Power 每平米功率 Power/m² 175W/㎡ 169W/㎡ 165 W/㎡...
  • Page 31 正面最大静态载荷 Maximum static load on the front 5400Pa 背面最大静态载荷 Maximum static load on rear side 2400Pa 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China. Made in China. Notes: Clamps are not recommended 2. Module Type of BMT-S1/004A 组件类型...
  • Page 32 正面最大静态载荷 Maximum static load on the front 5400Pa 背面最大静态载荷 Maximum static load on rear side 2400Pa 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China. Made in China. Notes: Clamps are not recommended 3. Module Type of BMT-S1/010A 组件类型...
  • Page 33 正面最大静态载荷 Maximum static load on the front 5400Pa 背面最大静态载荷 Maximum static load on rear side 2400Pa 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China. Made in China. Notes: Clamps are not recommended 4. Module Type of BMT-S1/018A 组件类型...
  • Page 34 正面最大静态载荷 Maximum static load on the front 5400Pa 背面最大静态载荷 Maximum static load on rear side 2400Pa 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China. Made in China. Notes: Clamps are not recommended 5. Module Type of BMT-S1/032B 组件类型...
  • Page 35 负载能力 Load Capacity 正面最大静态载荷 Maximum static load on the front 5400Pa 背面最大静态载荷 Maximum static load on rear side 2400Pa 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China. Made in China. Notes: Clamps are not recommended...
  • Page 36 Venus Tile User Installation Guide Manual 2021-9-30...
  • Page 37 Content 1.Description of the main construction of the Venus Tile ..........2 2.List of Installation Accessories ..................3 3.Installation Tools ......................3 4. Installation Tools and Spare Parts of Electrical Part ............3 5. Pre-installation Inspection .................... 4 6. The Installation of Venus Tile ..................4 7.
  • Page 38: Description Of The Main Construction Of The Venus Tile

    For the Australian market, Building Integrated PV Module installations must comply with the requirements of the National Construction Code and AS/NZS 5033. 1. Description of the main construction of the Venus Tile The front of Venus Tile The back of the Venus Tile Installation height:Altitude <2000m Fire rating: Venus Tile fire rating is CLASS A according to the corresponding certification standard (IEC61730-2-MST23)
  • Page 39: List Of Installation Accessories

    1. List of Installation Accessories Venus Tile accessories Cement tile accessories Component Installation Bracket Tile buckle Ridge tile installation screw name hooks Screw 2. Installation Tools installation tools Cutting machine (with Magnetic Philips Tool Steel measure Electric pistol Chalk Line woodworking Bits, length claw hammer...
  • Page 40: Pre-Installation Inspection

    Pre-installation Inspection  Venus Tile will generate electrical energy under light, so it is strictly forbidden to short-circuit the output cable, otherwise the output cable may overheat and cause the cable casing to melt.  Construction workers shall wear anti-skid shoes or anti-skid shoe covers during construction and deploy reliable anti-fall protection.
  • Page 41 surface. ②、(a) When the Venus Tile is temporarily leaning and placed, each stack should not exceed 15 pieces, otherwise the components may be damaged and fall off. ③、When the Venus Tile is temporarily leaning and placed, it is forbidden to squeeze the Venus Tile connecting cable between the two Venus Tile frames to avoid breaking the cable due to pressure.
  • Page 42 Counter batten installation 6、 Tile batten installation. ① (a) The size of the tile batten should be 30*30mm (optional, not smaller than this size). ② (a) The thickness of the cornice tile batten should be increased, with a distance of 285 mm between the centers of the upper row of tile batten and the tile batten on the eaves.
  • Page 43 Tile batten installation profile 7、 Venus Tile installation Sequence: Install from right to left in the same row, and install row by row from bottom to top. ① Install the matched tiles at the cornice first and the order of installation is from right to left, from bottom to top;...
  • Page 44 the Venus Tile is shown in the figure below: Hook centre 377.5mm from the edge of the left edge of the Venus Tile Hook centre 377.5mm from the edge of the left edge of the Venus Tile ③After confirming the location of the installation hooks, lay the bottom row of installation hooks first;...
  • Page 45 Layout of the installation hooks Layout details of the installation hooks ④After completing the installation of the installation hooks for the entire row of Venus Tile, install the matched tiles on the far right side of this row; (as shown below)
  • Page 46 Installation of the right side matched tile ⑤After installing the matched tiles on the right side, continue to lay the Venus Tile from right to left, the Venus Tile fall into the rabbet of the installation hooks, and then lay the matched concrete tiles on the left side of the Venus Tile to complete the installation of this row of tiles;...
  • Page 47 Venus Tile lap with right side matched tile (left profile) The lap of the left and right frame of Venus Tile (middle profile) Venus Tile lap with left side matched tile (right profile) ⑦The edge tiles, which are left or right lapped directly to the Venus Tile must be fixed with the tile batten using self-tapping screws.
  • Page 48 ⑪Repeat the installation of the Venus Tile and its matched tiles row by row from bottom to top until the entire roof installation is completed. 8、 Construction of the ventilated ridge (installation of brackets, waterproofing membrane and ridge tiles) 1 Fix the brackets using the snapped structural lines of the main and hip ridges as a reference line.
  • Page 49 2 Install the top row of edge tiles...
  • Page 50 3 Lay the waterproofing membranes 4 Install the ridge tiles: pre lay the ridge tiles and fix the ridge tile with the ridge tile screw after confirming that there are no problems. (main and hip ridges are installed in the same method) 9、...
  • Page 51 10、 Install the grounding wire for lightning protection 1 The grounding wire can be connected to the grounding hole on the left frame of the Venus Tile in the box uniformly before installation: install the serrated washer, grounding wire and self-tapping screw (diameter ≥ 4.8 mm) in turn and tighten the screw.
  • Page 52: Electrical Installation

    7. Electrical installation 7.1 Electrical performance The nominal values of the module electrical performance parameters such as Isc, Voc and Pmax have an error of ± 3% under standard test conditions (Irradiance 1000 W/m2, cell temperature 25°C, atmospheric mass AM1.5). When the modules are connected in a series, the final voltage is the sum of the series modules;...
  • Page 53 actual system voltage will depend on the module type and inverter selected ) and other values required for DC electrical components. The open circuit voltage correction factor can be calculated according to the following formula:CVoc=1-βVoc×(25-T). T is the minimum ambient temperature expected at the installation location of the system and β...
  • Page 54 Figure 7-2-1 Minimum bending radius of cable 7.3 Connectors Please keep the connector dry and clean, and ensure that the nut of the connector is fastened before connection. Do not connect the connector when the connector is wet, dirty or in other dangerous conditions. If the connector does not have a positive and a negative connection, the connector does not have waterproof function.
  • Page 55 angle of Venus Tile array. 7.6 Material preparation Please check whether the model and quantity of the delivered materials are correct according to the list on the configuration sheet 1、Venus Tile electrical wiring requirements ① Wiring shall have clear and understandable wire number identification; ②...
  • Page 56: Electrical Construction Technology

    Figure 7-2-1 Operating instructions for the connection of the Venus Tile jumper (view from the back of the roof) ③ After connecting a group of series connection as shown in the drawing, connect the remaining group of "+" and "-" terminal blocks into the bus kit or bus box; ④...
  • Page 57 ① Impact drill: used for drilling holes in the installation position of PVC pipe and pipe clamps; ② MC4 DC cable special crimping pliers: used for on-site production of DC MC4 plugs; ③ Multimeter and megohmmeter: used for cable conduction and insulation testing; ④...
  • Page 58 ⑦ Try to avoid high-temperature heating objects as far as possible; ⑧ Cable pipes need to be fixed; ⑨ Both ends of the AC and DC cables connected to the inverter and distribution box must be marked with the circuit cable number. Method of MC4 cable connector: ①...
  • Page 59 Verticality <1.5mm/m ⑤Different circuits and voltages, AC and DC cables should not be put in the same conduit ⑥ The cables in the pipe must not have joints; ⑦ MC4 plug connector is tightly connected. 8.2 Lightning protection and grounding 8.2.1 Lightning protection Lightening protection of the Sunshine array must comply with the requirements set out by AS 1768 and AS/NZS 5033.
  • Page 60 ② Check whether it can receive the data from the outside (remote service to read data). 8.2.7 Trial operation of power generation ① Ensure that the above inspection items meet the requirements; ② Close the circuit breaker on the DC input side; ③...
  • Page 61: Venus Tile Disassembly And Repair

    9. Venus Tile disassembly and repair If the installed Venus Tile is damaged or malfunctioned and must be replaced, it is necessary to repair and replace the damaged Venus Tile as soon as possible, please refer to the following detailed disassembly steps for repair and replacement of Venus Tile. 9.1 Venus Tile disassembly 1.
  • Page 62: Matters Need Attention

    9.2 Venus Tile replacement and installation  Slightly lift the tile on the left side of the position where the tile needs to be replaced  Place the replacement Venus Tile, so that they partially lap with the tiles on both sides ...
  • Page 63 负载能力 Load Capacity 正面最大静态载荷 Maximum static load on the front 5400Pa 背面最大静态载荷 Maximum static load on rear side 2400Pa 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China. Made in China. Notes: Clamps are not recommended...
  • Page 64 接插头 Connector 2 GZX1500 适有坡度 Apply gradient 17.5°-75° 负载能力 Load Capacity 正面最大静态载荷 Maximum static load on the front 5400Pa 背面最大静态载荷 Maximum static load on rear side 2400Pa 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China.
  • Page 65 Made in China. Notes: Clamps are not recommended 3.Module Type of BMT-V1/012A 组件类型 Module Type BMT-V1/012A(35W), 电气性能 Electrical Properties 测试条件 Testing Condition 1000W/m²,25℃,AM 1.5G spectrum 功率等级 Power 每平米功率 165W 开路电压 Voc 4.12V 短路电流 Isc 10.73A 最高功率点电流 Impp 10.19A 最高功率点电压 Vmpp 3.42V 功率...
  • Page 66 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China. Made in China. Notes: Clamps are not recommended 4.Module Type of BMT-V1/018A 组件类型 Module Type BMT-V1/018A(52W) 电气性能 Electrical Properties 测试条件 Testing Condition 1000W/m²,25℃,AM 1.5G spectrum 功率等级...
  • Page 67 负载能力 Load Capacity 正面最大静态载荷 Maximum static load on the front 5400Pa 背面最大静态载荷 Maximum static load on rear side 2400Pa 制造商信息 Manufacturer GOODWE POWER SUPPLY TECHNOLOGY CO., LTD No.208 Tongrui Rd., EDZ, Guangde, Anhui, China. Made in China. Notes: Clamps are not recommended...