Self-Test Mode Of Wired Remote Controller - Samsung AE040RXED Series Installation Manual

Air to water heat pump
Table of Contents

Advertisement

Self-test mode of wired remote controller

Use of self-test mode
Service mode
0
Please enter your
1 . If you want to use the various additional functions for your Wired Remote Controller, press the
same time for more than 3 seconds .
f The password entry screen appears .
f
2 . Enter the password, "0202, " and then press the
f The settings screen for installation/service mode appears .
f
3 . Select Self-Test Mode in Service Mode .
4 . Self-Test Mode consists of Self-Test Display that shows operation value satus and menus that can turn each component
on or off .
Self-Test Mode
Self-Test Mode Display
Water Pump
Booster Heater
DHW Valve (3 Way valve)
Zone#1 Valve
Back Up Heater1 + Water Pump
Back Up Heater2 + Water Pump
Back Up Boiler
Zone#2 Valve
Mixing Valve
PASSWORD
< OFF >
< OFF >
< OFF >
< OFF >
< OFF >
< OFF >
< OFF >
< OFF >
< OFF >
Service mode
Reset All Service Mode
Power Master Reset
ODU K3 Reset
Field Setting Value
Self-Test Mode
Indoor Unit Option
button .
Self-Tset Mode Display
Water Inlet Temp.: -00.0℃ to 000.0℃
Water Outlet Temp.: -00.0℃ to 000.0℃
Backup Heater Outlet Temp: -00.0℃ to 000.0℃
Mixing valve Outlet Temp.: -00.0℃ to 000.0℃
Tank Temp: -00.0℃ to 000.0℃
Indoor Ambient Temp.: -00.0℃ to 000.0℃
Self-Tset Mode Display
Indoor Ambient Temp. (Zone2): -00.0℃ to 000.0℃
Flow Temp. Sensor #1(Zone1): -00.0℃ to 000.0℃
Flow Temp. Sensor #2(Zone2): -00.0℃ to 000.0℃
Termostat #1(Zone #1): Coo/Heat
Termostat #2(Zone #2): Coo/Heat
Solar Panel On/Off: On/Off
ENGLISH-50