Typical application examples

• The application examples given below are for illustration purposes only .
• When the SAMSUNG Air-to-Water Heat Pump system is used in series with another heat source (e . g . gas boiler),
WARNING
ensure that the return water temperature not exceed 65 °C .
• The unit is only to be used in a closed water system . Application in an open water circuit can lead to excessive
corrosion of the water piping .
• SAMSUNG can not be responsible for incorrect or unsafe situations in the water system . Make sure that the
boiler, radiators, convectors, UFHs, FCUs, additional pumps, pipings, and controls in the water system are in
accordance with relevant local laws and regulations under the installer's responsibility .
• SAMSUNG shall not be held liable for any damage resulting from not observing this rule .
• SAMSUNG do not provide specific water system components such as Pressure relief valve, Air vent valve, buffer
tank and etc . Installers and end-users shall consider how to install the above designated components in overall
water system depending on the installation conditions . If the components are not installed in appropriate
location, the water system can not be operated as designed .
❋ ❋ The below examples are for illustration purposes only .
Application 1: Space heating + water heating
Outdoor
[ Supply Scope ]
Outdoor unit
Mechanical Room
Hot Water
Cold Water
Tank Integrated Hydro Unit
ENGLISH-11
Indoor
Room Controller
Zone Control
45°C
Water
pump #2
Tw2_z2
Water
pump #1
35°C
Tw2_z1
Balancing Vessel
Supply Header
Return Header
Radiators or Convectors
Supply Header
Return Header
Under-Floor Heating Coils