SAMSUNG EHS
Air Source Heat Pump Installation Guide
AE050JXYDEH/EU
AE090JXYDEH/EU
AE120JXYDEH/EU
AE140JXYDEH/EU
AE160JXYDEH/EU
Date of Issue: 30/01/17

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AE050JXYDEH/EU

  • Page 1 SAMSUNG EHS AE050JXYDEH/EU AE090JXYDEH/EU AE120JXYDEH/EU AE140JXYDEH/EU Air Source Heat Pump Installation Guide AE160JXYDEH/EU Date of Issue: 30/01/17...
  • Page 2: Table Of Contents

    Contents 1 - SAMSUNG EHS 20 - Heating Only Hybrids 1 - Air Source Heat Pump Installation Guide 21 - Heating Only Hybrid Wiring Diagram 1 - AE050JXYDEH/EU 23 - Wiring & Power Supply Information 1 - AE090JXYDEH/EU 24 - What comes with the unit?
  • Page 3: The Outdoor Unit (Boiler)

    The Outdoor Unit (Boiler) It is important to situate the unit within an open area with a good airflow, it is a good idea to choose a location that is not going to be blocked by plants, animals or anything else that may obstruct the airflow. Another factor to take into account is the mounting surface, make sure it is a flat, solid surface capable of withstanding the weight of the heat pump.
  • Page 4: Component List

    Component List Below is a list of components that you will need for each system. Hot Water Heating Heating & Reduced Multiple Combi Heating Only System Multifuels Only Only Hot Water Glycol System Heat Pumps Hybrid Hybrid Heat Pump Control Box Hot Water Cylinder Flexible Water Hoses 1 Pair 1 Pair 1 Pair...
  • Page 5 Samsung units can run anywhere between 0-3 bar pressure. Pump The circulation pump on the Samsung system will need to provide a minimum flow rate in order for the unit to perform correctly. The units need to have the following flow rates;...
  • Page 6 The heat pump changes the speed of the compressor to alter the output of the heat pump, much like adjusting the gas in a boiler. Samsung’s units can alter their output down to as low as 10% and has removed the cycling process.
  • Page 7 Do not attempt to use a standard non-heat pump cylinder as this will not work. The legionella function will be programmed into the Samsung controller to run once every week along with a daily function to ensure that the hot water is always up to temperature.
  • Page 8: Fast Connect

    This will control the pump and then send a signal to the unit to operate. The Samsung heat pump will adjust accordingly in a fully adjustable weather compensation mode and it will adjust the temperature of the water to match the ambient temperature.
  • Page 9: Wiring Fast Connect With One Heating Zone

    Wiring Fast Connect With One Heating Zone...
  • Page 10: Wiring Fast Connect To Multiple Heating Zones

    Wiring Fast Connect to Multiple Heating Zones...
  • Page 11: Heating & Hot Water Systems

    Heating & Hot Water Systems Low Loss Pump HP Pump Z1 Header, Buffer Tank, or Heat Exchanger Reduced Glycol System If the amount of glycol in the system is an issue and you want to reduce the amount then this can be done with a plate heat exchanger. This will need to be correctly sized for the duty and the flow and return temperatures of the system.
  • Page 12: Heating & Hot Water Systems Wiring Diagram

    Heating & Hot Water Systems Wiring Diagram...
  • Page 13: Multi Fuels

    Multi Fuels Buffer Tank with coil Pump HP Pump Z1 Stat set to 55°C Other sources into coil Operation • The temperature of the hot water is controlled with the cylinder sensor and the supplied controller. • The controller has a built in time clock control and has both daily and weekly sterilisation functions for legionella. • The system is able to be setup as open vented or pressurised. • The coil within the cylinder must be designed for use with a heat pump with a surface area of at least 2.5 m². • A guideline for sizing the cylinder would allow 55 litres of water per person each day. • It is recommended that the heat pump is sized so that it is able to reheat the cylinder within an hour. • As with most cylinders, it is possible to connect a PV system to the immersion heaters to reduce costs. A battery storage system is also a great way to help with this. • The heating system is controlled via a thermostat / time clock that is wired back to the internal control board (MIM). • There is not a limitation to the number of heating zones that can be connected to this setup. • This setup shows one heating zone. • Each heating zone will be controlled by its own thermostat or timer, this will operate it’s own zone valve which will then control the pump. This in turn will create the run signal for the heat pump to operate in heating mode.
  • Page 14: Multi Fuel Wiring Diagram

    Multi Fuel Wiring Diagram...
  • Page 15: Multiple Heat Pumps

    Multiple Heat Pumps Pump Pump Z1 Low Loss Header Buffer Tank Pump For a system that has more than one heat pump, each unit will need it’s own flow and return, this is easily done by using a hydraulic separator i.e. a buffer, header or with two heat exchangers.
  • Page 16: Multiple Heat Pumps, Heat Only Wiring Diagram

    Multiple Heat Pumps, Heat Only Wiring Diagram Master 2m Flow Switch Cable, Can be extended Communications Cable 2 core, 1mm, 16Vdc F1 F2 Remove MCB from unit Power Input 240V Power Supply 5kW unit - 16A 9kW unit - 20A 16kW unit - 32A Run Signal Pump HP...
  • Page 17: Multiple Heat Pumps, Heat & H/W Wiring Diagram

    Multiple Heat Pumps, Heat & H/W Wiring Diagram Master 2m Flow Switch Cable, Can be extended Communications Cable 2 core, 1mm, 16Vdc F1 F2 Remove MCB from unit Power Input 240V Power Supply 5kW unit - 16A 9kW unit - 20A Run Signal Pump HP 16kW unit - 32A...
  • Page 18: Combi Hybrids

    Combi Hybrids Combi Boiler Combi must be set to Boiler run at below 65°C A combi hybrid system is were a heat pump and a combi boiler is utilised on the same system. The heat pump is used only to provide space heating and cannot be used for DHW.
  • Page 19: Combi Hybrid Wiring Diagram

    Combi Hybrid Wiring Diagram...
  • Page 20: Heating Only Hybrids

    Heating Only Hybrids Combi Combi Boiler Boiler must be set to run at below 65°C Heat Exchanger, HP 2 HP 1 Buffer Tank or Low Loss Header A heating only hybrid system is a combination of a fossil fuel boiler and a heat pump. In a hybrid system the heat pump only provides heating and cannot heat the domestic hot water.
  • Page 21: Heating Only Hybrid Wiring Diagram

    Heating Only Hybrid Wiring Diagram...
  • Page 23: Wiring & Power Supply Information

    Remote controller The Samsung control is usually installed in close proximity to the control box and is mostly used for commissioning purposes. To connect this to the control board you will need a 2 core 0.50.75 mm 2 core flex that connects to F3 & F4 in the controller to F3 & F4 on the control...
  • Page 24: What Comes With The Unit

    What comes with the unit? The first thing that you will see when you open the box (unless you open it upside down) should be the sensor cables. The blue sensor cable is used to measure the temperature inside the cylinder and connects into a yellow socket on the control board labelled CNS042. The sensor should be located in the top half of the cylinder above the immersion heater.
  • Page 25: Start-Up Procedure

    Start-Up Procedure Before connecting the heat pump to the system, a thorough system flush is highly recommended in line with the Building Regulations for England and Wales, Part L, 2006. Using a power flusher, fill the system with a mixture of water and 25-30% glycol, there is no pressure sensor in the unit so it can operate from open vented to 3 bar max.
  • Page 26: Field Settings

    Field Settings The field settings are used in order to set/alter the way the unit will operate, each system/setup will have different field settings. There are different groups of settings and they are; 20’s - There are for the weather compensation and temperature controls in heating 30’s - These are for the cylinder 40’s - Are for backup boilers and hybrid systems...
  • Page 27: Cylinder Timer

    Cylinder Timer To avoid the cylinder getting cold or the function being switched off, it is always advised that two timers are set for each day. The first timer is set for 3am and the second and 3pm. The timers will ensure that the cylinder is up to temperature at all times, it is normal that no off timers are set. To setup the timer you will need to follow the below steps;...
  • Page 28: Electrically Testing The Unit

    Electrically testing the unit To test each electrical component on the system you can use this mode/ function to make sure everything is electrically correct before starting the unit. To gain access to this mode, press the right and left buttons together for 6 seconds or until the controller displays TEST (7E57).
  • Page 29: Checking Flow Rate Before Starting The Heat Pump

    Checking flow rate before starting the heat pump The flow rate through the system is high and must maintain this at all times. If the flow rate drops to low E911 will show on the screen. If there is a separator in the system i.e a buffer, the flow rate is much easier to achieve and maintain. If there is not a separator then there will need to be extra tests carried out.
  • Page 30: Starting The Unit In Heating Mode

    The compressor will start after 3 minutes After the compressor starts the pipework will begin to heat up and you will be able to check the flow temperature by using the Samsung controller. Press the oval view button, by doing so you will see 4 different sensor temperatures;...
  • Page 31: Starting The Unit In Hot Water Mode

    Starting the unit in hot water mode To start the unit in hot water mode press DHW on/off button in the top right of the controller to start the unit. If done correctly, the tap symbol appears with dots next to it, press the mode button until you have 2 dots, by doing so it will activate the immersion heater after the preset time in the field settings.
  • Page 32: Handover Of The System

    Handover of the System Leave the following pages with the Homeowner Thank you for buying a Samsung EHS heat pump system, your Samsung heat pump heats the house and hot water cylinder much like a normal fossil fuel boiler, however, there are a couple of differences which you should take notice of. The installer of the system should have provided you with a room stat to control the temperature, or if you have underfloor heating you will have a stat in each room. To turn on your heating, you only need to turn up your thermostat. To turn of your heating, turn it back down. Once the unit starts up it will take time to get to temperature, it is not instant. Within 10 minutes you should feel the radiators beginning to warm up. Weather compensation and water law: The temperatures of the radiators will not be what you may be used to if you used to have boiler, as well as this the heat pump will run in what is known as weather compensation mode.
  • Page 33: General Advice

    Hot Water The temperature of the cylinder is controlled by the Samsung controller, this is setup to maintain the temperature of the water between 43°C and 50°C. As hot water is used, the heat pump will be constantly monitoring the temperature inside the cylinder, the hot water heating has priority over space heating. If the cylinder falls by 5°C from the setpoint, the heat pump will automatically switch to hot water heating.
  • Page 34: Warranty Registration

    If the installer wishes to do so, they can offer a warranty to you/end user that covers the whole system. The standard warranty terms for the Samsung heat pump is 3 years, if the installer is a Samsung certified installer then the warranty terms are 7 years.
  • Page 35: Commissioning & Maintenance Sheet

    Where was the unit purchased Date installed Date delivered ( Proof of delivery required) Warranty Starts from this date Date commissioned Samsung approved installer? Would you like to be an approved installer? Warranty Years Required 3 / 5 / 7 Years Installation Address...
  • Page 36: Maintenance Of Monobloc Systems

    Maintenance of Monobloc Systems The Samsung EHS units should be maintained at least once per year to comply with the warranty terms and RHI. Maintenance procedure To start the maintenance procedure, stop the unit, clean the dirt filter within manufacturer’s recommendations and replace.
  • Page 37: Problems And Faults

    One thing to check is that the heat pump turns off when all the stats are turned down or off. When the unit is set up it should have AU on the Samsung controller meaning that the heat pump will only operate when it receives a run signal back to B22 or B24 in the control box.
  • Page 38 Dead remote controller but red lights are on the indoor PCB On first startup you will notice two red LEDs light up, after around 4 minutes the screen will light up. If the controller hasn’t started after around 4 minutes and the control board has the red LEDs lit up, there is a small brown eeprom PCB plugged into the board.
  • Page 39 Cold Weather Protection my unit won’t start The Samsung heat pump has a variety of cold weather protection functions, these are; The heat pump will not start if the fluid in the system is 10°C or lower, if the sensors within the heat pump detect that the heat exchanger has reached 10°C or less there are two things that the unit will do;...
  • Page 40 SOLFEX Ltd Energy Arena Units 3-5 Charnley Fold Industrial Estate Bamber Bridge Preston Lancashire PR5 6PS Tel: 01772 312 847 Fax: 01772 335 277 Email: heatpumpsales@solfex.co.uk www.solfex.co.uk...