Self-Test Mode Of Wired Remote Controller; Use Of Self-Test Mode - Samsung MIM-E03CN Installation Manual

Air to water heat pump control kit
Hide thumbs Also See for MIM-E03CN:
Table of Contents

Advertisement

Self-test mode of wired remote controller

Use of self-test mode

Service mode
0
Please enter your
PASSWORD
1. If you want to use the various additional functions for your Wired Remote Controller, press the
same time for more than 3 seconds.
The password entry screen appears.
2. Enter the password, "0202, " and then press the
The settings screen for installation/service mode appears.
3. Select Self-Test Mode in Service Mode.
4. Self-Test Mode consists of Self-Test Mode Display that shows operation value satus and menus that can turn each
component on or off.
Self-Test Mode
Self-Test Mode Display
Water Pump
Booster Heater
DHW Valve (3 Way valve)
Zone#1 Valve
Back Up Heater1 + Water Pump
Back Up Heater2 + Water Pump
Back Up Boiler
Zone#2 Valve
Mixing Valve
button.
Self-Test Mode Display
< OFF >
< OFF >
< OFF >
< OFF >
< OFF >
< OFF >
< OFF >
Self-Test Mode Display
< OFF >
< OFF >
Service mode
Reset All Service Mode
Power Master Reset
ODU K3 Reset
Field Setting Value
Self-Test Mode
Indoor Unit Option
Water Inlet Temp.: -00.0
to 000.0
Water Outlet Temp.: -00.0
to 000.0
Backup Heater Outlet Temp: -00.0
to 000.0
Mixing valve Outlet Temp.: -00.0
to 000.0
Tank Temp: -00.0
to 000.0
Indoor Ambient Temp.: -00.0
to 000.0
Indoor Ambient Temp. (Zone2): -00.0
to 000.0
Flow Temp. Sensor #1(Zone1): -00.0
to 000.0
Flow Temp. Sensor #2(Zone2): -00.0
to 000.0
Termostat #1(Zone #1): Coo/Heat
Termostat #2(Zone #2): Coo/Heat
Solar Panel On/Off: On/Off
and
buttons at the
29

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents