Concrete curing function

When pipes of floor heating are installed, operation for reinforcing concrete curing is applied . (Period of operation: 23 days)
Entering procedure
1 . After turning off the DIP switch K3 of indoor unit (Default ON), power off and on the indoor unit . The operation for
concrete curing starts automatically . (If blackout occurs and communictation restarts later, operation will continue . )
2 . Temperature of discharge water is controlled as time goes on like below .
Temp.
60
55
50
45
40
35
30
25
20
1
2
3
4
5
6
Initial
Classification
Heating
Time
96
72
Temperature
30
55
3 . Remaining days are displayed on the wired remote controller during operation but key operation is unavailable .
Remaining days
are displayed .
❋ ❋ If an error is displayed, concrete curing function does not work .
7
8
9
10
11
12
13
14
Step raise
24
24
24
24
24
30
35
40
45
50
Concrete Curing
Remaining days:
ENGLISH-67
15
16
17
18
19
20
21
Heating
Step down
144
24
24
24
55
50
45
40
Day
22
23
Total
(Hour)
24
24
552
35
30
-