7.Configuration Of Connectors And Terminal Blocks; Power Connectors Xa , Xb , Xc , Xd And Terminal Blocks - Panasonic MINAS A6N Manual

Ac servo driver
Hide thumbs Also See for MINAS A6N:
Table of Contents

Advertisement

7.Configuration of connectors and terminal blocks

7-1 Power connectors XA , XB , XC , XD and terminal blocks

Size A, B 100 V / 200 V
Pin No.
Symbol
5
L1
4
L2
XA
3
L3
2
L1C
1
L2C
6
5
4
XB
3
2
1
W
*Tighten the Earth screw with a torque of M4: 1.0 to 1.2 N · m.
R6.0
Name
Main power input
terminal
Control power
input terminal
P
Regenerative
resistor connecting
N
terminal
B
U
Motor output
V
terminal
Earth
Single phase
100 V
100-120 V
Use L1 and L3 terminal for single phase input
Single or 3 phase
200-240 V
200 V
Use L1 and L3 terminal for single phase input
Single phase
100 V
100-120 V
Single phase
200 V
200-240 V
 To use an external regenerative resistor (customer prepared), connect an
external regenerative resistor between P and B.
In addition, parameter setting is required for the regenerative resistor. For
details, refer to "Technical Refarence - Functional Specification-"
 Do not connect anything to the N terminal.
 Connect each phase of the motor winding.
U: U phase
V: V phase
 When using Voice coil motor, connect the following.
U: U phase
W: W phase
Do not connect anything to V terminal.
For details, refer to "Technical Reference - Function Specification-"
Earth terminal for grounding
Motion Control Business Unit, Panasonic Corporation
No. SX-DSV03224-33-
Description
+ 10 %
50/60 Hz
- 15 %
+ 10 %
50/60 Hz
- 15 %
+ 10 %
50/60 Hz
- 15 %
+ 10 %
50/60 Hz
- 15 %
W: W phase