3.5 Connecting T8

3.5.1 Spot reading with the INFIELD7 handheld

The T8 is fitted with an 8-pin plug. The plug can be connected to an
INFIELD7 handheld measuring device. The INFIELD7 displays and
stores the soil water tension, the soil temperature and the filling
status.

3.5.2 Connection to a data logger

For connecting T8 to a data logger or any other data acquisition
devices connecting and extension cables are required. Find T8
cables  in  the  chapter  "Accessories".
The supply voltage does not has to be stabilized.
If the Tensiometer is not permanently powered the warm-up
before a measurement should be at least 10 seconds.
The Tensiometer plug should be covered with the supplied
protective cap anytime the T8 is not connected to an extension
cable.
Never connect the signal outputs of the T8 to a supply voltage
source!
The supply voltage must not exceed 18 VDC.
Tightly screw together all plugs of connecting cables (CC-8/...) or
extension cables (EC-8/...). Do this again after a few minutes as
only then the connections will be absolutely water proof.
23/58