Error codes for CBD6S troubleshooting:
Error Code
8
9
10
11
12
13
14
15
16
17
18
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Name
Unexpected Rest
LIN error
Power fail
Channel count
changed
Position difference
Short circuit
Checksum
Power limit
Key error
No safety
Missing initialistion
plug
Channel 1 missing
Channel 2 missing
Channel 3 missing
Channel 4 missing
Channel 5 missing
Channel 6 missing
Channel 1 type
Channel 2 type
Channel 3 type
Channel 4 type
Channel 5 type
Channel 6 type
Channel 1 pulse
Channel 2 pulse
Channel 3 pulse
Description
unexpected rest caused by software er -
ror or external rest
An error occurs on LIN bus
A power failure occured or power regu
lator adjusted below 10%
Number of channels connected to the
system has changed since last initialisa -
tion
Difference between minimum and maxi
mum position of a reference has been
exeeded
Short circuit has been detected while
running
Position checksum check failed, all chan -
nels have position lost
The system has reached its power limita -
tion
Illegal key combination or change of
keys
Safety function has not allowed move
ment but input active
A special service tool is required to
change number of channels to the sys -
tem
Actuator missing
Actuator type has changed since initiali
sation, or detected wrong
Actuator type has changed since intiali -
sation, or detected wrong, or it is not
the same as the first actuator
Too many pulse errors
-
-
-
-
Need help?