Intialisation
NOTE: Before INITIALISATION is carried out, the ANTI COLLISION feature is disabled.
Please ensure you remove any objects or items from under the desk frame to
Please repeat the below steps in the event of a power interuption.
1. Press & hold the switch until the legs are fully retracted - this is the END STOP position.
Release the switch
2. Immediately press and hold the switch for approx. 6 seconds. The legs will travel out
5mm and then retract back to the END STOP position.
3. It may be necessary to perform the intialisation process twice as the system can be in
different modes at start up.
4. The legs are now initialised.
5. Initialisation is also required after a
Factory Reset
NOTE: Must be done prior to first use
avoid any collision whilst the desk is initialising.
power interuption
or
relocation of the desk.