Reinforced door bar
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 35
Fig. 26
Abb. 25
2.
Fig. 28
PV1820: Frame through-bolting of the lock casings in case of unstable mounting options (e.g. thin
lightweight construction walls)
Mounting (use longer M8 screws if necessary):
1. Drill through holes Ø 9 mm in the corresponding position through the door frame. Drill out
from the outside Ø 13 mm and 35 mm deep.
2. Insert the threaded sleeve including the metal plates into the screw holes from the outside
as shown in the illustration (Fig. 30) and screw it together through the lock casing from the
inside (use washers if necessary). Shorten the screws if necessary.
3. Press the cover on from the outside.
78
Fig. 27
1.
2.
Fig. 29
2.
1.
3.
3.
2.
1.
Fig. 30
PA1018N: Mounting set for outward opening doors
Note: Screw connection suitable for door thicknesses of 38 to 80 mm.
Drill through holes ø 9 mm, in the corresponding position through the door panel and drill out
ø 13 mm and 35 mm deep from the outside.
Insert the screw sleeves including the metal plates into the screw holes from the outside as
shown in the illustration (Fig. 31) and screw together through the security door bar from the
inside. Shorten the screws if necessary.
Press the cover on from the outside.
Fig. 31
External escutcheon PR2800
The escutcheon is screwed with 2 screws (M6) through the door from the inside (Fig. 32).
M6x35 = for door thicknesses to 55 mm, M6x45 = for door thicknesses to 65 mm.
Longer hexagonal socket screws M6 must be used for stronger doors.
Fig. 32