Instruction Manual
Spa Table MLE
Gharieni Group GmbH
Am Schürmannshütt 24
D - 47441 Moers
SERIAL NUMBER
).
+49 (0)2841/88300-0
+49 (0)2841/88300-999
+49 (0)2841/88300-40
service@gharieni.de
www.gharieni.de
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MLE and is the answer not in the manual?

Questions and answers

Summary of Contents for GHARiENi MLE

  • Page 1 ➢ Fax: +49 (0)2841/88300-999 ➢ Customer service hotline: +49 (0)2841/88300-40 ➢ E-mail: service@gharieni.de ➢ Web: www.gharieni.de Empty field for entering the SERIAL NUMBER The serial number of the MLE is on the rating plate (s. chapter 7. R ATING PLATE...
  • Page 2: Table Of Contents

    Reading the complete IM is essential for its proper and confident use and will help you to operate the MLE to your entire satisfaction. Our MLE is very robust and has a long operating life if it is operated properly.
  • Page 3 11. Smart Thermo heating system (optional equipment) ..........30 11.1 Operating of the Smart Thermo heating system ..........31 12. Cleaning and maintenance of the MLE ..............36 12.1 Cleaning and care of the PU upholstery .............. 37 12.2 Cleaning of the housing and of the fittings ............37 12.3 Cover of the upholstery ..................
  • Page 4 19. EC-Declaration Of Conformity .................. 50 20. Status of edition ......................51 Do not dispose of the MLE together with your domestic waste. The Spa Table must be disposed of at a collecting centre for recyclable electric and electronic appliances. Do not remove the symbol from...
  • Page 5: Safety Information

    Copies of this instruction manual are available upon request. ➢ The Gharieni Group GmbH shall not be held responsible for any damages, direct or indirect, caused to people, animals or objects resulting from negligence or non- compliance with the instructions contained herein.
  • Page 6: Signal Words

    3. The technical data of your energy supplier must meet the data on the rating plate of the MLE. 4. Do not modify the plug provided with the MLE, if it will not fit the outlet, have a proper outlet installed by a qualified electrician (not covered by the guarantee).
  • Page 7 / or the plug yourself. RISK OF ELECTRIC SHOCK! 12. Always unplug the MLE if it is not used for a longer period of time. 13. Always disconnect the MLE from the mains before cleaning and / or maintenance.
  • Page 8 Do not use attachments / accessories not recommended by the manufacturer. 16. Never operate the MLE if it has a damaged cord or plug, if it is not working properly, if it has been damaged or if it has become wet.
  • Page 9 AWAY! 31. Never extend the castors while any person is on the MLE. Do not move the MLE on its castors if any person or load is on the MLE; otherwise you damage the substructure or castors. 32. The MLE must never be used (neither with nor without castors) for the carrying or transporting of persons or heavy loads.
  • Page 10: Intended Use

    ❖ The MLE is a versatile Spa Table. You can use it for e.g. cosmetic applications or full body massages in dry rooms, etc. No other use is permitted: it will affect your guarantee rights.
  • Page 11: Preliminary Remarks

    5. Delivery and unpacking of the MLE 5.1 Delivery ❖ The MLE is delivered and packed in a cardboard on a special pallet (s. fig. below). The MLE is in complete horizontal position and the upholstery is installed. ELIVERY BY THE...
  • Page 12: Unpacking

    WARNING! While unpacking, the packaging materials (polythene bags, polystyrene pieces, etc.) should be kept away from children and pets. RISK OF INJURY! CHOKING HAZARD! ❖ The MLE is delivered and packed in a cardboard on a special pallet (s. fig. below). PACKAGING TAPES PPER CARDBOARD...
  • Page 13: Assembly And Transport Of The Mle

    2. Do not open the upper cardboard (B) but lift it carefully and vertically as a whole from the MLE and from the special pallet (C). For this purpose, you will need two persons (one person each on the short sides / D of the cardboard).
  • Page 14: Use Of The Special Carrying Aids

    (Fig. similar: Fig serves as an example only) PECIAL CARRYING AIDS You also need the special carrying aids (s. fig. above) to lift the MLE from the special pallet. The proper use of the special carrying aids is described below in chapter 6.2.1.
  • Page 15 Figures similar: All following figures serve as examples only. 1. To move the MLE from the special pallet, you must raise it by 8 - 10 cm first. Plug in the MLE to do this. Then press the corresponding push button of the manual control panel which is on one side on a suspension unit / (button 1, s.
  • Page 16 8. Carry or transport the MLE using all four special carrying aids only; otherwise you can damage the MLE irreparably. 9. Store the carrying aids in a safe place. If the MLE have to be carried or transported at a later point of time (e.g. when moving), it is only possible when using the four special carrying aids.
  • Page 17: Extendable / Retractable Castors

    WARNING! Always ensure that the MLE stands on its solid adjustable feet. If the MLE stands on its mobile castors only, there is a RISK OF ROLLING AWAY! WARNING! RISK OF CRUSHING your toes / feet while lowering or moving the MLE.
  • Page 18 2. Lift the cover plate (A) of the upper casing vertically and remove it (s. fig. below). 3. The lever (B) to extend the castors mechanically is at the bottom of the now open casing (s. fig. below). 4. Pull the lever (B) towards you to extend the castors. Thereby, you have to overcome a resistant point.
  • Page 19: Rating Plate

    Before moving the MLE, unplug it, roll up the power cord properly and store the power cord in such a way, that you cannot roll over it when moving the MLE. Do not retract the castors unless the MLE stands at its desired site and you have checked that the cables are not located under the MLE.
  • Page 20 1. Set the backrest in upright position (button 3 of the manual control panel / s. fig. in chapter 10.1 M ANUAL CONTROL PANEL 2. You have to remove the cover plate (A / s. below; fig. 1) to gain access to the rating plate (D / s.
  • Page 21: Upholstery Of The Mle

    8. Upholstery of the MLE ❖ The MLE is equipped with a comfortable one-piece choco coloured upholstery (s. fig. below). ❖ The inner material of the upholstery is made of high quality foam material.
  • Page 22: Characteristics

    9.1 Characteristics ❖ The MLE is a versatile Spa Table. You can use it for e.g. cosmetic applications or full body massages in dry rooms. ❖ The MLE is equipped with a high-quality comfort padding made of PU. ❖ The MLE is available in the colour „wenge“ with dark brown corners and choco coloured upholstery.
  • Page 23: Before Initial Use

    ➢ The armrests and the headrest of the MLE are pneumatically adjustable. ➢ The leg section of the MLE is not adjustable. 9.3 Before initial use ➢ Before initial operation, please check that all components are present (s. chapter 3. S ) and that they are not visibly damaged.
  • Page 24 EG SECTION ➢ Not adjustable EAT SECTION ➢ Thigh section to knee bend section NEE BEND INCLINATION OF THE SEAT SECTION ➢ The of the seat section is adjustable by the INCLINATION electrically adjustable KNEE BEND ➢ s. chapter 10.4 A DJUSTMENT OF THE INCLINATION OF THE SEAT SECTION ACKREST...
  • Page 25: Gas Pressure Springs

    (instructions are not depending on the adjustment of the lying surface). Failure to do so can cause permanent damage to the construction of the MLE. RISK OF TIPPING! RISK OF DISINTEGRATION! RISK OF INJURY! The headrest is freely and manually adjustable (s. fig. 3, 4 and 5 below).
  • Page 26 For this purpose, the headrest is equipped with a separate upholstery part, which can be removed (s. below; fig. 6). ❖ Using a gel cushion (s. fig. 7, optional available at Gharieni) on the headrest upholstery can additionally support the face of the person to be treated (see also chapter 14.1 G...
  • Page 27: Armrests

    NOTICE! The maximum loading capacity of the armrests is 25 kg. 9.8 Leg section ❖ The leg section of the MLE is not adjustable. 9.9 Backrest ❖ The backrest of the MLE can be adjusted electrically (s. chapter 10.3 DJUSTMENT OF THE BACKREST...
  • Page 28: Adjustment Of The Mle

    10. Adjustment of the MLE ❖ The electrical adjustments of the MLE are carried out using the manual control panel (MCP). ❖ The pneumatic adjustments of the MLE (armrests / headrest) are carried out using a gas pressure spring by means of a lever.
  • Page 29: Adjustment Of The Work Height

    WARNING! Ensure that no parts of the body or items are between the parts of the MLE while adjusting the treatment position. RISK OF CRUSHING! NOTICE! For safety reasons, the MLE moves only while pressing a key of the MCP. When you stop pressing, all moving-operation will stop immediately.
  • Page 30: Adjustment Of The Inclination Of The Seat Section

    ❖ The direction of movement (up or down) is indicated by the arrow-symbols. 11. Smart Thermo heating system (optional equipment) ❖ The lying surface of MLE can be heated to maximize the treatment comfort. The Smart Thermo is a pre-programmed and fully automatic heating system which allows a comfortable operation.
  • Page 31: Operating Of The Smart Thermo Heating System

    Thermo function by pressing the OFF-button on the control panel to avoid heat accumulation. 4. Disconnect the MLE from the mains when it is not used for a longer period of time, e.g. during the night. WARNING! Persons suffering from acute pain, venous disorders, low...
  • Page 32 ONTROL PANEL OF THE MART HERMO HEATING SYSTEM : -ON- UTTON : -OFF- UTTON EMPERATURE SELECTION BUTTON IME SELECTION BUTTON 2 blue LEDs 2 green LEDs 2 yellow LEDs 2 orange LEDs 2 red LEDs...
  • Page 33 UTTON ❖ Press this button to switch on the Smart Thermo. 1. When the Smart Thermo is switched on, it starts heating at the maximum heating / power level for 5 minutes (level 5: the 2 red LEDs (E) are illuminated). 2.
  • Page 34 The selected heating / power level will be displayed on the LEDs above the operating buttons: Level 1 blue LEDs (A) Press button one time Level 2 green LEDs (B) Press button two times Level 3 yellow LEDs (C) Press button three times Level 4 orange LEDs (D)
  • Page 35 XAMPLE You wish to set a medium heating / power level (level 3) of 30 minutes. Please proceed as follows: 1. Switch on the Smart Thermo by pressing the button -ON- 2. Then select the . Press this button TEMPERATURE SELECTION BUTTON repeatedly until the two yellow LEDs (C) are illuminated (s.
  • Page 36: Cleaning And Maintenance Of The Mle

    ❖ Do not wear any arm and finger decoration such as rings or bracelets while carrying out any cleaning or maintenance operations. Otherwise you can scratch and damage the upholstery and / or the material of the base of the MLE unintentionally.
  • Page 37: Cleaning And Care Of The Pu Upholstery

    12.1 Cleaning and care of the PU upholstery ❖ The outer material of the upholstery of the MLE is made of PU (polyurethane). ❖ Clean the PU using a soft cloth only provided with a small amount of a cleaning agent.
  • Page 38: Malfunctions (Possible Causes And Troubleshooting)

    Massages incl. larger amounts of oil (e.g. ➢ Only when using this protective Ayurveda applications with oil pouring): cover, the structure and the electrical components of the MLE are protected. 13. Malfunctions (possible causes and troubleshooting) ALFUNCTION OSSIBLE CAUSE...
  • Page 39: Repair Of The Mle

    2. Repairs and modifications must be carried out by Gharieni Group GmbH or a person authorized by Gharieni Group GmbH. 3. The electrical installation of the room the MLE is installed in must meet the current legal regulations at the site where the MLE is operated.
  • Page 40: Optionally Available Accessories

    6. All electric components are designed for continuous operation. Leave the MLE connected when it is used every day. 7. Check the power cord regularly for signs of damage. 8. When the power cable is damaged, it must be replaced by the manufacturer or an authorized aftersales service or a qualified professional only.
  • Page 41: Towels For Nose Slots (Disposable Cloths)

    EL CUSHIONS FOR NOSE SLOTS RTICLE NUMBER  For detailed information regarding the right size and suitable version for your Spa Table please contact the Gharieni customer service. We will be glad to advise you! 14.2 Towels for nose slots (disposable cloths) ❖...
  • Page 42: Neck Rest -Dentalax

    (fig similar: colour and workmanship may vary depending on the model selected)  For detailed information regarding the right size and suitable version for the headrest of your Spa Table please contact the Gharieni customer service. We will be glad to advise you! 14.4 Protective covers...
  • Page 43: Protective Covers Made Of Pu

    (fig. similar: fig. serves as an example only)  For detailed information regarding the right size and suitable version of the covers as well as the compatibility with your Spa Table please contact the Gharieni customer service. We will be glad to advise you! 14.4.2 Protective covers made of PU...
  • Page 44: Ayurveda Cover

     For detailed information regarding the right size and suitable version of the covers as well as the compatibility with your Spa Table please contact the Gharieni customer service. We will be glad to advise you! 14.4.3 Ayurveda cover ❖ An A for Spa Tables (s.
  • Page 45: Protective Foot Cover

    14.4.4 Protective foot cover ❖ A (s. fig. below) for Spa Tables is optional available for PROTECTIVE FOOT COVER an additional charge. ❖ The is made of stable, transparent plastic and is fixed PROTECTIVE FOOT COVER with a hook and loop fastener [consisting of a Velcro and a fleece strip (Counter Velcro)].
  • Page 46: Conditions Of Transport, Storage And Operation

    6.2.2 E XTENDABLE RETRACTABLE CASTORS ❖ On uneven surfaces, you must not use the castors of the MLE. In this case, lift the MLE during transport using the special carrying aids only (s. chapter 6.2.1 SE OF THE SPECIAL CARRYING AIDS ❖...
  • Page 47: Technical Data

    16. Technical data ENERAL DATA Total Length 204 cm Total Width 84 cm Adjustable height approx. 54 cm - 88 cm Inclination of the headrest approx. +30 , -30 Inclination of the backrest approx. 0 - 75 Lifting capacity 250 kg Max.
  • Page 48: Waste Management

    CHOKING HAZARD! RISK OF INJURY! 2. Do not dispose of the MLE together with your domestic waste. Old and unused Spa Tables must be sent for disposal to the responsible recycling centre for electric appliances.
  • Page 49: Guarantee Provisions

    Claims must be filed within 8 days after the delivery of the Gharieni MLE. Apart from the cases specified in the supply agreement, the guarantee is void when: The malfunctioning is attributable to the operator.