Do you have a question about the ChamScan partech RDO-X Stainless Steel and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for In-situ ChamScan partech RDO-X Stainless Steel

  • Page 1 RDO-X Stainless Steel Operator’s Manual Information subject to change without notice. In-Situ, In-Situ logo, Baro Merge, BaroTROLL, HERMIT, HydroVu™, iSitu, Pocket-Situ, RDO, RuggedCable, RuggedReader, SmarTROLL™, TROLL, VuSitu, and Win-Situ are trademarks or registered trademarks of In-Situ Inc. 2016. All rights reserved. This product may be covered by patents identified at www.in-situ.com/ ©...
  • Page 2: Table Of Contents

    Maintenance ....................................7 How to Install and Replace the RDO Cap ..........................7 Disposal ......................................7 How to Clean the Instrument ..............................7 Technical Specifications ..................................8 Declaration of Conformity ................................. 9 Technical Support ....................................10 Returning Equipment for Repair ............................10 1-970-498-1500 www.in-situ.com...
  • Page 3: Introduction

    2 years. The sensor operates with optical luminescence measurement technology described in Standard Method 4500-O and In-Situ Methods 1002-8-2009, 1003-8-2009, 1004-8-2009 (EPA Approved). When the probe initiates a reading, an LED emits blue light, which excites lumiphore molecules in the sensing element.
  • Page 4: Getting Started

    Monitor). Wire the cable into the terminals Power up the Control Point 2.0 Configure. or 7300w2. Reinstall the terminal cover. Connect power to the Use the arrow keys to select Sensor Config. controller and turn it on. Press Menu. 1-970-498-1500 www.in-situ.com...
  • Page 5 Slide the RDO cap away Align the flat edge inside Replace the guard and guard. from the instrument. Do the cap with the flat edge calibrate the instrument. not twist cap. on the instrument. Slide the new cap into place. 1-970-498-1500 www.in-situ.com...
  • Page 6: Calibration

    Press OK CONFIG and press OK. once the value has stabilized. 0% Saturation Calibration 0% Saturation calibration can be accessed from Service Mode on the monitor. Contact ChemScan or Partech for guidance before attempting to calibrate at 0% Saturation. 1-970-498-1500 www.in-situ.com...
  • Page 7: Storage And Maintenance

    In the UK and EU, Partech can provide recycling of your old Partech equipment and can sometimes recycle other manufacturers’ equipment when replaced with Partech equipment. Trade-in options may be available for new equipment. Contact Partech for more information. 1-970-498-1500 www.in-situ.com...
  • Page 8: Technical Specifications

    95% of value in less than 60 seconds @ 77° F (25° C) Measurement Principle Optical measurement of Luminescence Light Source Blue LED Temperature Measurement Thermistor Flow Rate No flow necessary EMC 2014/30/EU IEC 61000-6-2:2005 Compliance EN 55011:2009 1-970-498-1500 www.in-situ.com...
  • Page 9: Declaration Of Conformity

    Radio disturbance characteristics for scientific and medical equipment The CE mark is affixed accordingly. Ben Kimbell VP of R&D In-Situ, Inc. June 23, 2021 Copyright © 2015 In-Situ Inc. This document is confidential and is the property of In-Situ Inc. Do not distribute without approval. 1-970-498-1500 www.in-situ.com...
  • Page 10: Technical Support

    Ask our service department if you need packing advice. • Contact name and phone number • Return address for equipment • Description of fault or service required • Any special safety precautions because of nature of application 1-970-498-1500 www.in-situ.com...
  • Page 11 Ask our service department if you need packing advice. • Contact name and phone number • Return address for equipment • Description of fault or service required • Any special safety precautions because of nature of application 1-970-498-1500 www.in-situ.com...